title: Cu-HTTP | ||
definition: | ||
value: NXmpes | ||
version: "1.0" | ||
method: XPS | ||
start_time: 2022-04-08T11:47:02.0200Z | ||
experiment_institution: Helmholtz-Zentrum Berlin | ||
experiment_facility: BESSY II | ||
experiment_laboratory: XPS beamline | ||
user: | ||
name: Alexei Nefedov | ||
email: alexei.nefedov@kit.edu | ||
affiliation: Karlsruhe Institute of Technology (KIT), Institut für Funktionelle Grenzflächen | ||
address: KIT | ||
orcid: 0000-0001-9361-8333 | ||
instrument: | ||
energy_resolution: | ||
type: calibrated | ||
resolution: | ||
value: 0.1 | ||
unit: eV | ||
source_xray: | ||
type: Synchrotron X-ray Source | ||
name: BESSY II | ||
probe: x-ray | ||
device_information: | ||
vendor: Helmholtz-Zentrum Berlin | ||
model: BESSY II | ||
identifier: null | ||
current: | ||
value: 298 | ||
unit: mA | ||
beam_xray: | ||
distance: | ||
unit: mm | ||
value: 0.0 | ||
#current: | ||
#value: 30 | ||
#unit: "pA" | ||
analyser: | ||
name: Hemispherical Analyser dummy | ||
description: hemispherical | ||
device_information: | ||
vendor: Scienta Omicron | ||
model: null | ||
identifier: null | ||
collectioncolumn: | ||
device_information: | ||
vendor: Scienta Omicron | ||
model: null | ||
identifier: null | ||
scheme: angular dispersive | ||
energydispersion: | ||
device_information: | ||
vendor: Scienta Omicron | ||
model: null | ||
identifier: null | ||
scheme: hemispherical | ||
pass_energy: | ||
unit: eV | ||
APERTURE[entrance_slit]: | ||
description: Analyser slit Nr. 3 | ||
shape: curved slit | ||
size: | ||
value: 0.4 | ||
unit: mm | ||
detector: | ||
amplifier_type: channeltron | ||
detector_type: Multi-anode | ||
manipulator: | ||
POSITIONER[positioner_x]: | ||
value: | ||
value: 15.5 | ||
unit: cm | ||
POSITIONER[positioner_y]: | ||
value: | ||
value: 11 | ||
unit: cm | ||
POSITIONER[positioner_z]: | ||
value: | ||
value: 36 | ||
unit: cm | ||
POSITIONER[positioner_phi]: | ||
value: | ||
value: 45 | ||
unit: degree | ||
sample: | ||
chemical_formula: Au | ||
description: Au foil on standard sample holder | ||
situation: vacuum | ||
sample_history: | ||
sample_preparation: | ||
start_time: 2022-04-08T11:25:00.200Z | ||
end_time: 2022-04-08T11:45:00.200Z | ||
description: sputter cleaned with Ar ions for 20 min | ||
method: Ar sputtering | ||
PHYSICAL_PROCESS[sample_loading]: | ||
start_time: 2023-03-08T10:49:12+01:00 | ||
end_time: 2023-03-08T10:52:47+01:00 | ||
description: loaded in the endstation and transferred to analysis chamber | ||
method: vacuum transfer |