62 changes: 59 additions & 3 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
@@ -1,8 +1,64 @@
# Changelog

## [1.0.38] 2022-04-28
### Updated
- updated documentation
## [1.1.0-beta.0] 2022-04-28
### Changed
**Action required** Breaking changes!
In order to support configuration by GUI some configuration options needs to be adapted.
- `PLC_LightBulb`:
- renamed option `minValue` -> `minBrightnessValue` and changed default value from `20` to `0`
- renamed option `maxValue` -> `maxBrightnessValue`
- renamed option `minStep` -> `minBrightnessStep`
-`PLC_TemperatureSensor`
- renamed option `minValue` -> `minTemperatureValue` and changed default value from `-50` to `-270`
- renamed option `maxValue` -> `maxTemperatureValue` and changed default value from `110` to `100`
- renamed option `minStep` -> `minTemperatureStep` and changed default value from `0.5` to `0.1`
-`PLC_HumiditySensor`
- renamed option `minValue` -> `minHumidityValue`
- renamed option `maxValue` -> `maxHumidityValue`
- renamed option `minStep` -> `minHumidityStep`
- `PLC_Thermostat`
- renamed option `minValue` -> `minTargetTemperatureValue` and changed default value from `15` to `10`
- renamed option `maxValue` -> `maxTargetTemperatureValue` and changed default value from `27` to `38`
- renamed option `minStep` -> `minTargetTemperatureStep` and changed default value from `0.5` to `0.1`
- renamed option `minHumidityValue` -> `minTargetHumidityValue`
- renamed option `maxHumidityValue` -> `maxTargetHumidityValue`
- renamed option `minHumidityStep` -> `minTargetHumidityStep`
- renamed option `mapGetCurrent` -> `mapGetCurrentHeatingCoolingState`
- renamed option `mapGetTarget` -> `mapGetTargetHeatingCoolingState`
- renamed option `mapSetTarget` -> `mapSetTargetHeatingCoolingState`
- `PLC_SecuritySystem`
- renamed option `mapGetCurrent` -> `mapGetSecuritySystemCurrentState`
- renamed option `mapGetTarget` -> `mapGetSecuritySystemTargetState`
- renamed option `mapSetTarget` -> `mapSetSecuritySystemTargetState`
- the obsolete options `mapGet` and `mapSet` are no longer supported
- `PLC_HumidifierDehumidifier`
- renamed option `mapGetCurrent` -> `mapGetCurrentHumidifierDehumidifierState`
- renamed option `mapGetTarget` -> `mapGetTargetHumidifierDehumidifierState`
- renamed option `mapSetTarget` -> `mapSetTargetHumidifierDehumidifierState`
- `PLC_LockMechanismBool`
- renamed option `invert` -> `invertLockState`
- renamed option `get_LockCurrentState` -> `get_LockCurrentStateBool`
- renamed option `get_LockTargetState` -> `get_LockTargetStateBool`
- renamed option `set_LockTargetState` -> `set_LockTargetStateBool`
- renamed option `set_Secured` -> `set_LockTargetStateBool_Secured`
- renamed option `set_Unsecured` -> `set_LockTargetStateBool_Unsecured`
- renamed option `forceCurrentState` -> `forceCurrentLockState`
- `PLC_LockMechanism`
- renamed option `forceCurrentState` -> `forceCurrentLockState`
- `PLC_GarageDoorOpener`
- renamed option `forceCurrentState` -> `forceCurrentGarageDoorState`

- ### Added
- `PLC_Thermostat`
- option `minTemperatureValue`
- option `maxTemperatureValue`
- option `minTemperatureStep`
- option `minHumidityValue`
- option `maxHumidityValue`
- option `minHumidityStep`

### Fixed
- fixed **http control**

## [1.0.37] 2022-04-23
### Fixed
Expand Down