A fully browser-based Modbus RTU master/client tool that communicates with Modbus slave devices over a serial port using the Web Serial API. No installation, no dependencies, no server — just open the HTML file in Chrome or Edge and start querying.
- Web Serial API — connects directly to RS-232/RS-485 serial ports from the browser (Chrome 89+ / Edge 89+)
- Configurable port settings — baud rate (1200–115200), data bits (7/8), stop bits (1/2), parity (none/even/odd)
- Adjustable timeout — configurable response timeout from 100ms to 10,000ms
- CRC-16/Modbus — automatic CRC generation on transmit and verification on receive
| Code | Function | Type |
|---|---|---|
| FC01 | Read Coils | Read |
| FC02 | Read Discrete Inputs | Read |
| FC03 | Read Holding Registers | Read |
| FC04 | Read Input Registers | Read |
| FC05 | Write Single Coil | Write |
| FC06 | Write Single Register | Write |
| FC15 | Write Multiple Coils | Write |
| FC16 | Write Multiple Registers | Write |
When reading registers (FC03/FC04), each register in the response can be individually assigned a data type for interpretation. The following types are supported:
| Type | Size | Registers Used |
|---|---|---|
| 8-bit INT | 8-bit signed | 1 |
| 16-bit INT | 16-bit signed | 1 |
| 32-bit INT | 32-bit signed | 2 |
| 8-bit UINT | 8-bit unsigned | 1 |
| 16-bit UINT | 16-bit unsigned | 1 |
| 32-bit UINT | 32-bit unsigned | 2 |
| 64-bit UINT | 64-bit unsigned | 4 |
| 32-bit Float | IEEE 754 single | 2 |
| 64-bit Float | IEEE 754 double | 4 |
| String4 | 4-char ASCII | 2 |
| String6 | 6-char ASCII | 3 |
| String8 | 8-char ASCII | 4 |
| String12 | 12-char ASCII | 6 |
| String16 | 16-char ASCII | 8 |
Multi-register types (32-bit, 64-bit, strings) automatically span the correct number of consecutive registers. A "Copy #1 → All" button lets you set the first register's type and apply it to every register in one click.
Byte order options for multi-byte types:
- Big-Endian (AB CD) — most common
- Little-Endian (BA DC)
- Mid-Big / Word-Swap (CD AB)
- Mid-Little / Byte-Word-Swap (DC BA)
Many Modbus device manuals use documentation addresses like 40001 for the first holding register, but the actual Modbus protocol uses 0-based addressing. The Minus Offset feature bridges this gap:
- Enter the documentation address (e.g.
40001) as the Start Address - Set the Offset Value to
40001 - The tool subtracts the offset and sends wire address
0on the protocol - The response table still displays your original documentation addresses
A live preview shows the calculated wire address before you send, and the communication log displays both addresses when offset is active.
Enable automatic repeated querying at a configurable interval (100ms–60,000ms). Useful for monitoring live values. Toggle on/off with a checkbox — the tool will re-send the current query at each interval.
Create named profiles to label registers, coils, and inputs for specific Modbus slave devices. Profiles make the response data table much more readable by showing human-friendly names alongside raw addresses.
Each profile stores:
- Profile Name — Identifies the device (e.g. "Schneider PM5110")
- Slave ID — The device's Modbus address, automatically applied when the profile is loaded
Each profile entry defines:
- Type — Coil, Discrete Input, Holding Register, or Input Register
- Address — The register/coil address (using documentation addressing, e.g. 40001)
- Label — A human-readable name (e.g. "Motor Speed", "Tank Level", "Alarm Status")
- Data Type — Optionally pre-assign a data type (overrides the default uint16 for registers)
Automatic FC tab configuration: When a profile is active and you click a function code tab, the tool automatically:
- Sets the Start Address to the lowest address defined in the profile for that register type
- Sets the Quantity to cover all defined addresses (accounting for multi-register data types)
- Enables Minus Offset with the standard base address (1 for coils, 10001 for discrete inputs, 30001 for input registers, 40001 for holding registers)
This means you can simply load a profile, click a FC tab, and immediately send a query — no manual address configuration needed.
Profile management features:
- Save — Stores profiles in the browser's localStorage for persistence across sessions
- Export JSON — Downloads the profile as a
.jsonfile for backup or sharing - Import JSON — Loads a previously exported profile file
- Load / Delete — Manage saved profiles from the list in the profile editor
- Clear Active — Removes the currently active profile without deleting it from storage
When a profile is active, a pink badge appears in the header showing the profile name, and a Label column is added to the response data table. Profile data types are automatically applied to the per-register type selectors.
Every response is displayed in three formats:
- HEX — space-separated hexadecimal bytes
- BIN — space-separated 8-bit binary bytes
- ASCII — printable characters with
·for non-printable bytes
- Timeout — clear message when no response is received
- CRC errors — detected and reported with guidance to check wiring/baud rate
- Modbus exceptions — decoded by name (Illegal Function, Illegal Data Address, Illegal Data Value, Slave Device Failure)
- Validation errors — caught before sending (invalid register values, etc.)
When an error occurs, the response data table is replaced with a clear error message to prevent confusion with stale data.
The following sections can be collapsed/expanded by clicking their headers to reduce clutter:
- Response Data
- Data Type per Register
- Raw Response Frame
- Communication Log
Timestamped log of all TX (sent), RX (received), and error events with full hex frame data and timing information. Includes a clear button and collapse toggle.
- Browser: Google Chrome 89+ or Microsoft Edge 89+
- Serial adapter: Any USB-to-RS232 or USB-to-RS485 adapter recognised by the operating system
- No server or installation required — runs entirely in the browser from a local file
Note: The Web Serial API is not supported in Firefox or Safari.
- Open
modbus-master.htmlin Chrome or Edge - Configure serial port settings (baud rate, data bits, stop bits, parity) in the sidebar
- Click "Connect" — the browser will prompt you to select a serial port
- Set the slave ID, start address, and quantity
- Select a function code tab (FC01–FC16)
- Click "Send Query" to execute the Modbus request
- View the response in the data table, with optional data type interpretation
- Check "Enable Minus Offset" in the sidebar
- Enter the offset value (e.g.
40001for holding registers,10001for discrete inputs,30001for input registers) - Enter your documentation address as the Start Address
- The wire preview below will show the calculated protocol address
- Send queries as normal — the tool handles the address translation
- Send a register read query (FC03 or FC04)
- The "Data Type per Register" section appears with a dropdown for each register
- Select the desired type for each register (or set the first and click "Copy #1 → All")
- Choose the byte order if working with multi-byte types
- The table updates automatically to show the interpreted values
- Click the "Profiles" button in the header
- Enter a profile name (e.g. "Schneider PM5110") and the device's Slave ID
- Click "+ Add Entry" to define each register/coil label:
- Select the type (Coil, Discrete, Holding, Input)
- Enter the address number (use documentation addresses, e.g. 40001 for holding register 0)
- Type a descriptive label
- Optionally choose a data type (for registers)
- Click "Save Profile" to store it locally and activate it
- Now simply click any FC tab — the start address, quantity, and minus offset are auto-configured from the profile
- Click "Send Query" — the Label column shows your defined names in results
- To share profiles, use "Export JSON" and "Import JSON"
- Ensure you are connected to a serial port
- Set the desired polling interval in milliseconds
- Check "Enable Auto-Polling" to start
- Uncheck to stop polling
- Select a write function code (FC05, FC06, FC15, or FC16)
- The "Write Value(s)" panel appears with guidance for the expected format:
- FC05 (Single Coil):
1,0,true,false,on,off - FC06 (Single Register): An integer between 0 and 65535
- FC15 (Multiple Coils): Comma or space-separated
1/0values - FC16 (Multiple Registers): Comma or space-separated integers (0–65535)
- FC05 (Single Coil):
- Click "Send Query" to execute the write
This is a single self-contained HTML file. There are no external dependencies, build steps, or server requirements. All HTML, CSS, and JavaScript are inline.
| Browser | Supported |
|---|---|
| Google Chrome 89+ | ✅ |
| Microsoft Edge 89+ | ✅ |
| Opera 76+ | ✅ |
| Firefox | ❌ (no Web Serial API) |
| Safari | ❌ (no Web Serial API) |
- Fonts: JetBrains Mono and Outfit — both licensed under the SIL Open Font License 1.1
- Web Serial API: A native browser API provided by Chromium-based browsers
This project is released under The Unlicense — dedicated to the public domain.