Skip to content

INESCTEC/ATTEST-WP2-T2.5-Day-Ahead-Aggregator-Tool

 
 

Repository files navigation

Inputs

Building parameters

  • Electrical heater - Installed 0 - no, 1 - yes
  • Electrical heater - Maximum power kW
  • Electrical heater - Efficiency/COP -
  • Gas heater - Installed 0 - no, 1 - yes
  • Gas heater - Maximum power kW
  • Gas heater - Efficiency/COP -
  • PV - Installed 0 - no, 1 - yes
  • PV - Maximum power kW
  • Storage - Installed 0 - no, 1 - yes
  • Storage - Maximum power kW
  • Storage - Maximum SOC kWh
  • Storage - Mininum SOC kWh
  • Storage - Initial SOC kWh
  • Storage - Efficiency -
  • District heating - Installed 0 - no, 1 - yes
  • District heating - Maximum power kW
  • Gas - Load 0 - no, 1 - yes
  • Thermal model building - Resistance oC /kW
  • Thermal model building - Capacity kWh/ oC
  • Thermal model building - Initial temperature oC
  • Thermal model building - Maximum and mininum temperature per hour oC
  • Energy consumption - Electricity consumption kWh
  • Energy consumption - Gas consumption kWh
  • Energy consumption - Heat consumption kWh

Electrical networks paramters

  • Branches - Branch connections -
  • Branches - R Ω
  • Branches - X Ω
  • Branches - Branch limits A
  • Buses - Voltage limits p.u.
  • Buses - Reference bus number -
  • Buses - Reference bus voltage p.u.
  • Buses - Load/building/resource connections -
  • Buses - System base MVA

Gas networks parameters

  • Pipeline - Pipeline connections -
  • Pipeline - Length m
  • Pipeline- Diameter mm
  • Buses - Pressure limit Bar
  • Buses - Reference bus number -
  • Buses - Load/building/resource connections -

Heat networks parameters

  • Load - Location -
  • Load - Return temperature oC
  • Generator - Type w – electricity , g - gas
  • Generator - Electrical, gas and heat bus connection -
  • Generator - Supply node temperature oC
  • Generator - Power limits kW
  • Generator - Efficiency/COP -
  • Pipeline - Connections -
  • Pipeline - Length m
  • Pipeline - Diameter mm
  • Pipeline - Heat transfer coefficient W/ oC
  • Pipeline - Supply pipeline temperature limits oC
  • Pipeline - Return pipeline temperature limits oC
  • Pipeline - Pipeline mass flow limits kg/s
  • Pipeline - Ambient temperature oC
  • Pipeline - Friction of pipeline -
  • Buses - Supply bus temperature limits oC
  • Buses - Return bus temperature limits oC
  • Buses - Pressure limits Pa
  • Buses - Load/building/resource connections

Weather parameters

  • Solar profile %
  • Outside temperature oC

Prices

  • Electricity - Day-ahead energy prices €/MWh
  • Electricity - Secondary reserve day-ahead energy prices – upward and downward €/MWh
  • Electricity - Secondary reserve ratios – upward and downward %
  • Gas - Day-ahead energy prices €/MWh

Outputs

  • Electricity - Energy bid (per hour, per electrical bus) MWh
  • Electricity - Upward secondary reserve band bid (per hour, per electrical bus) MW
  • Electricity - Downward secondary reserve band bid (per hour, per electrical bus) MW
  • Gas - Energy bid (per hour, per gas node) MWh

How to Run

Run

main.py

About

Task 2.5 -- Day-Ahead Aggregator Tool

Topics

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published

Languages

  • Python 100.0%