5 changes: 5 additions & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -3,6 +3,11 @@
## future release

* Upgrade `mqtt` to get rid of `async-mqtt` (https://github.com/Jalle19/eda-modbus-bridge/issues/95)
* Remove flaky support for "PRO" unit naming scheme
* Add rudimentary way of differentiating between different automation types
* Disable "heating/cooling allowed" on legacy EDA units, fixes crash (https://github.com/Jalle19/eda-modbus-bridge/issues/105)
* Disable "eco" mode switch on older units (https://github.com/Jalle19/eda-modbus-bridge/issues/104)
* Add optional sensors for control panel temperature, supply fan speed and exhaust fan speed (https://github.com/Jalle19/eda-modbus-bridge/issues/96)

## 2.7.1

Expand Down
266 changes: 142 additions & 124 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -127,58 +127,92 @@ Returns a JSON object like this:

```json
{
"flags": {
"away": false,
"longAway": false,
"overPressure": false,
"maxHeating": false,
"maxCooling": false,
"manualBoost": false,
"summerNightCooling": false
"flags": {
"away": false,
"longAway": false,
"overPressure": false,
"cookerHood": false,
"centralVacuumCleaner": false,
"maxHeating": false,
"maxCooling": false,
"manualBoost": false,
"summerNightCooling": false
},
"readings": {
"freshAirTemperature": -2.9,
"supplyAirTemperatureAfterHeatRecovery": 16.8,
"supplyAirTemperature": 17,
"wasteAirTemperature": 0.3,
"exhaustAirTemperature": 19.3,
"exhaustAirTemperatureBeforeHeatRecovery": -40,
"exhaustAirHumidity": 51,
"heatRecoverySupplySide": 88,
"heatRecoveryExhaustSide": 85,
"heatRecoveryTemperatureDifferenceSupplySide": 19.8,
"heatRecoveryTemperatureDifferenceExhaustSide": 19,
"mean48HourExhaustHumidity": 37,
"cascadeSp": 170,
"cascadeP": 0,
"cascadeI": 130,
"overPressureTimeLeft": 0,
"ventilationLevelActual": 75,
"ventilationLevelTarget": 65
},
"settings": {
"overPressureDelay": 5,
"awayVentilationLevel": 30,
"awayTemperatureReduction": 2,
"longAwayVentilationLevel": 49,
"longAwayTemperatureReduction": 0,
"temperatureTarget": 17,
"coolingAllowed": true,
"heatingAllowed": true,
"awayCoolingAllowed": true,
"awayHeatingAllowed": false,
"longAwayCoolingAllowed": true,
"longAwayHeatingAllowed": false
},
"deviceInformation": {
"softwareVersion": 2.17,
"automationType": "EDA",
"fanType": "EC",
"coolingTypeInstalled": null,
"heatingTypeInstalled": "EDE/MDE",
"modelType": "Pingvin",
"serialNumber": 0,
"modelName": "Pingvin eco EDE/MDE",
"modbusAddress": 1
},
"alarmHistory": [
{
"name": "TE30ExtractAirCold",
"description": "TE30 Extract air cold",
"state": 0,
"date": "2024-01-21T06:21:00.000Z"
},
"readings": {
"freshAirTemperature": 7.3,
"supplyAirTemperatureAfterHeatRecovery": 21.7,
"supplyAirTemperature": 21.4,
"wasteAirTemperature": 11.2,
"exhaustAirTemperature": 22.5,
"exhaustAirTemperatureBeforeHeatRecovery": -40.0,
"exhaustAirHumidity": 45,
"heatRecoverySupplySide": 94,
"heatRecoveryExhaustSide": 74,
"heatRecoveryTemperatureDifferenceSupplySide": 14.4,
"heatRecoveryTemperatureDifferenceExhaustSide": 11.3,
"mean48HourExhaustHumidity": 39,
"cascadeSp": 170,
"cascadeP": 0,
"cascadeI": 100,
"overPressureTimeLeft": 0,
"ventilationLevelActual": 60
},
"settings": {
"overPressureDelay": 60,
"awayVentilationLevel": 30,
"awayTemperatureReduction": 2,
"longAwayVentilationLevel": 60,
"longAwayTemperatureReduction": 0,
"temperatureTarget": 17
},
"deviceInformation": {
"fanType": true,
"heatingConfigurationMode": 1,
"familyType": 0,
"serialNumber": 0,
"softwareVersion": 217
},
"alarms": [
{
"name": "ServiceReminder",
"description": "Service reminder",
"state": 1, // 2 = Active, 1 = Dismissed
"date": "2021-10-24T11:28:00.000Z"
},...
]
...
],
"deviceState": {
"normal": true,
"maxCooling": false,
"maxHeating": false,
"emergencyStop": false,
"stop": false,
"away": false,
"longAway": false,
"temperatureBoost": false,
"co2Boost": false,
"humidityBoost": false,
"manualBoost": false,
"overPressure": false,
"cookerHood": false,
"centralVacuumCleaner": false,
"heaterCooldown": false,
"summerNightCooling": false,
"defrosting": false
}
}

```

### GET /mode/{flag}
Expand Down Expand Up @@ -244,112 +278,94 @@ Every topic is prefixed by `eda/`, so to subscribe to everything the application
The following read-only topics are regularly published:

```
eda/status
eda/alarm/CoolingError
eda/alarm/EHError
eda/alarm/EHPDA
eda/alarm/EmergencyStop
eda/alarm/ExtractFanPressureError
eda/alarm/ExtractFilterDirty
eda/alarm/FireRisk
eda/alarm/HPError
eda/alarm/HRError
eda/alarm/ReturnWaterCold
eda/alarm/ServiceReminder
eda/alarm/SupplyFanPressureError
eda/alarm/SupplyFilterDirty
eda/alarm/TE10SupplyAirAfterHeaterCold
eda/alarm/TE10SupplyAirAfterHeaterHot
eda/alarm/TE20RoomTempHot
eda/alarm/TE30ExtractAirCold
eda/alarm/TE30ExtractAirHot
eda/alarm/TE5SupplyAirAfterHRCold
eda/mode/away
eda/mode/centralVacuumCleaner
eda/mode/cookerHood
eda/mode/longAway
eda/mode/overPressure
eda/mode/maxHeating
eda/mode/maxCooling
eda/mode/manualBoost
eda/mode/maxCooling
eda/mode/maxHeating
eda/mode/overPressure
eda/mode/summerNightCooling
eda/readings/freshAirTemperature
eda/readings/supplyAirTemperatureAfterHeatRecovery
eda/readings/supplyAirTemperature
eda/readings/wasteAirTemperature
eda/readings/cascadeI
eda/readings/cascadeP
eda/readings/cascadeSp
eda/readings/exhaustAirHumidity
eda/readings/exhaustAirTemperature
eda/readings/exhaustAirTemperatureBeforeHeatRecovery
eda/readings/exhaustAirHumidity
eda/readings/heatRecoverySupplySide
eda/readings/freshAirTemperature
eda/readings/heatRecoveryExhaustSide
eda/readings/heatRecoveryTemperatureDifferenceSupplySide
eda/readings/heatRecoverySupplySide
eda/readings/heatRecoveryTemperatureDifferenceExhaustSide
eda/readings/heatRecoveryTemperatureDifferenceSupplySide
eda/readings/mean48HourExhaustHumidity
eda/readings/cascadeSp
eda/readings/cascadeP
eda/readings/cascadeI
eda/readings/overPressureTimeLeft
eda/readings/supplyAirTemperature
eda/readings/supplyAirTemperatureAfterHeatRecovery
eda/readings/ventilationLevelActual
eda/readings/ventilationLevelTarget
eda/settings/overPressureDelay
eda/settings/awayVentilationLevel
eda/readings/wasteAirTemperature
eda/settings/awayCoolingAllowed
eda/settings/awayHeatingAllowed
eda/settings/awayTemperatureReduction
eda/settings/longAwayVentilationLevel
eda/settings/awayVentilationLevel
eda/settings/coolingAllowed
eda/settings/heatingAllowed
eda/settings/longAwayCoolingAllowed
eda/settings/longAwayHeatingAllowed
eda/settings/longAwayTemperatureReduction
eda/settings/longAwayVentilationLevel
eda/settings/overPressureDelay
eda/settings/temperatureTarget
eda/alarm/TE5InletAfterHeatExchangerCold
eda/alarm/TE10InletAfterHeaterCold
eda/alarm/TE10InletAfterHeaterHot
eda/alarm/TE20RoomHot
eda/alarm/TE30OutletCold
eda/alarm/TE30OutletHot
eda/alarm/HPFault
eda/alarm/HeaterFault
eda/alarm/ReturnWaterCold
eda/alarm/LTOFault
eda/alarm/CoolingFault
eda/alarm/EmergencyStop
eda/alarm/FireRisk
eda/alarm/ServiceReminder
eda/alarm/HeaterPressureSwitch
eda/alarm/InletFilterDirty
eda/alarm/OutletFilterDirty
eda/alarm/InletFanPressureAbnomaly
eda/alarm/OutletFanPressureAbnomaly
eda/deviceState/normal
eda/deviceState/maxCooling
eda/deviceState/maxHeating
eda/deviceState/emergencyStop
eda/deviceState/stop
eda/deviceState/away
eda/deviceState/longAway
eda/deviceState/temperatureBoost
eda/deviceState/co2Boost
eda/deviceState/humidityBoost
eda/deviceState/manualBoost
eda/deviceState/overPressure
eda/deviceState/cookerHood
eda/deviceState/centralVacuumCleaner
eda/deviceState/heaterCooldown
eda/deviceState/summerNightCooling
eda/deviceState/defrosting
eda/status
```

Boolean values are expressed as `ON` or `OFF`.

The following topics are published to once during application startup:

```
eda/deviceInformation/fanType
eda/deviceInformation/unitType
eda/deviceInformation/automationType
eda/deviceInformation/coolingTypeInstalled
eda/deviceInformation/heatingTypeInstalled
eda/deviceInformation/familyType
eda/deviceInformation/fanType
eda/deviceInformation/heatingTypeInstalled
eda/deviceInformation/modbusAddress
eda/deviceInformation/modelName
eda/deviceInformation/modelType
eda/deviceInformation/serialNumber
eda/deviceInformation/softwareVersion
eda/deviceInformation/modelName
eda/deviceInformation/softwareVersionInt
```

The following topics can be written to in order to control the operation of the ventilation unit:

```
eda/mode/away/set
eda/mode/longAway/set
eda/mode/overPressure/set
eda/mode/maxHeating/set
eda/mode/maxCooling/set
eda/mode/manualBoost/set
eda/mode/summerNightCooling/set
eda/settings/overPressureDelay/set
eda/settings/awayVentilationLevel/set
eda/settings/awayTemperatureReduction/set
eda/settings/longAwayVentilationLevel/set
eda/settings/longAwayTemperatureReduction/set
eda/settings/temperatureTarget/set
eda/mode/+/set
eda/settings/+/set
```

* `eda/mode/` topics take the values `ON` or `OFF`
* `eda/settings/` topics take integer values
* `eda/mode/` topics take the boolean values (`ON` or `OFF`)
* `eda/settings/` topics take integer or boolean values

### Home Assistant MQTT discovery

Expand All @@ -358,7 +374,7 @@ in Home Assistant automatically through the MQTT integration. The following enti

* sensors for all readings
* numbers (configurable) for settings
* switches for the ventilation modes
* switches for the ventilation modes and settings
* binary sensors for the alarms

![](https://raw.githubusercontent.com/Jalle19/eda-modbus-bridge/master/docs/readme_ha1.png "Home Assistant device info")
Expand All @@ -382,7 +398,9 @@ in Home Assistant automatically through the MQTT integration. The following enti
do its job.

* Older firmware (e.g. Pingvin devices with software version 2.01) only support a smaller list of Modbus registers, so
some functionality may be missing. Open an issue if you feel like something isn't working that should be working.
some functionality may be missing. Open an issue if you feel like something isn't working that should be working.
Unsupported functionality is indicated by the corresponding sensor being disabled in Home Assistant, and the readings
missing from the `/summary` HTTP endpoint.

## Troubleshooting

Expand Down
Loading
Loading