Skip to content

Try to model a smart home, modelled with metacontrol, with Maude

Notifications You must be signed in to change notification settings

JulianePa/Maude_Metacontrol

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

A Formal Model of Metacontrol in Maude

Overview

This repository contains a formal model, written in Maude, of a Smart Home Use Case that uses Metacontrol.

Download and run

To run the program, Maude needs to be installed. Guidelines for the installation can be found here.

To start Maude and load all files, first go to the additional_modules directory:

cd maude/additional_modules/

Then run:

maude test.maude

which will not only load the test.maude file, but also all other files that are necessary for the execution (the other modules are loaded within the test.maude file).

Test

Scenario displayed in paper

Once the files are loaded, you can simulate how the controllers work by using the frew command. You have to specify how many rewrite steps the system should do, otherwise it will not terminate. The 200 time steps that are displayed in the paper can be simulated by using frew[1400]. The test.maude file contains initial configurations to test the Comfort-, the Eco-, and the Metacontroller. They can be tested by running

frew[1400] initComfort .
frew[1400] initEco .
frew[1400] init initMetacontr .

where the first command uses a configuration with only the Comfort controller, the second uses a configuration with only the Eco controller, and the third uses a configuration with the Comfort-, Eco-, Degraded A -, Degraded B -, and Metacontroller.

Other initial configurations with for example a different initial temperature or air quality, can be tested by changing the respective values in test.maude.

If you want to see which rules are applied during the rewriting process, run

set print attribute on .

This can be reverted by running

set print attribute off .

Scenarios with breaking actuators

To simulate how the controllers work if an actuator breaks, first load the files as described before. Then, edit the break.maude file located at the maude/additional_modules/ folder. There, you can change the time step when the heater breaks in the if condition of the rule HeaterBreaks and the time step when the water heater breaks in the if condition of the rule WaterheaterBreaks.

For example, to change the time step when the water heater breaks to 75, you need to change the 2000000 value in the following rule to 75:

crl [WaterheaterBreaks] :
  < WH :Waterheater | Status: WHS, Broken: no, A >
  < C :Clock | Timesteps: TS, Time: TI, TempLog: TL, AqLog: AL >
  =>
  < WH :Waterheater | Status: whOff, Broken: yes, A >
  < C :Clock | Timesteps: TS, Time: TI, TempLog: TL, AqLog: AL >
  if TS >= 2000000
  [print "rule: [WaterheaterBreaks]"] .

Like this:

crl [WaterheaterBreaks] :
  < WH :Waterheater | Status: WHS, Broken: no, A >
  < C :Clock | Timesteps: TS, Time: TI, TempLog: TL, AqLog: AL >
  =>
  < WH :Waterheater | Status: whOff, Broken: yes, A >
  < C :Clock | Timesteps: TS, Time: TI, TempLog: TL, AqLog: AL >
  if TS >= 75
  [print "rule: [WaterheaterBreaks]"] .

Note that we assume that only one actuator can be broken at the same time and that broken actuators do not get repaired. Thus, you should only change one of these values. The results displayed in the paper were obtained if the heater, respectively water heater, broke after 75 time steps. Therefore, to reproduce these results, change one of the values to 75 and run the same frew commands as above.

Variability of the environment

To inject variability of the environment, we implemented two different ways the environment changes over time. They can be found in the file physics.maude that is located in the folder maude/smart_home_model/ in the definition of the function variabilityEnvir. Here, you can also define your own environment variability. To use another way the environment changes, go in the test.maude file and change the version of the environment to the desired one. Thus, if you want to run experiments with the second way of changing the environment, change < Environment | Version: 1 > to < Environment | Version: 2 > in all three initial configurations and run the same frew commands as above.

Automatic generation of log files and plots

If you also want to create the plots that show the temperature and air quality changes for the Comfort-, Eco-, and Metacontroller, then you have to go to the test.maude file and delete eof, which can be found at the bottom of the file. The end of the file should now look like this:

endm
frew[1400] initComfort .
frew[1400] initEco .
frew[1400] initMetacontr .
quit

If Maude is still running, run quit to quit it. Otherwise, go to the main folder. By running

./run_smart_home.sh

the initial configurations with the Comfort-, Eco-, and Metacontroller will be executed for 200 time steps and plots of their performance will be displayed.

If you want to test the system again without plotting the graphs, then insert eof again after endm, i.e. the end of the test.maude file should look like this:

endm
eof
frew[1400] initComfort .
frew[1400] initEco .
frew[1400] initMetacontr .
quit

Structure of the modules

maude_structure

Additional documents

The appendices for the paper can be found here.

Acknowledgments

This project has received funding from the European Union’s Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement No. 956200.

Pleave visit our website for more info on our project.

REMARO Logo

About

Try to model a smart home, modelled with metacontrol, with Maude

Resources

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published