99 changes: 86 additions & 13 deletions custom_components/solvis_control/const.py
Original file line number Diff line number Diff line change
Expand Up @@ -184,27 +184,40 @@ class ModbusFieldConfig:
unit="%",
device_class="power_factor",
state_class="measurement",
multiplier=0.01,
),
ModbusFieldConfig( # A02.Pumpe Warmwasser
name="a02_pumpe_warmwasser",
address=33281,
unit="%",
device_class="power_factor",
state_class="measurement",
multiplier=0.01,
),
ModbusFieldConfig( # A03.Pumpe HK1
name="a03_pumpe_hk1",
ModbusFieldConfig( # A03.Pumpe HKR 1
name="a03_pumpe_hkr_1",
address=33282,
unit="%",
device_class="power_factor",
state_class="measurement",
multiplier=0.01,

),
ModbusFieldConfig( # A05.Pumpe Zirkulation
name="a05_pumpe_zirkulation",
ModbusFieldConfig( # A04.Pumpe HKR 2
name="a04_pumpe_hkr_2",
address=33283,
unit="V",
device_class="voltage",
state_class="measurement",
multiplier=0.01,
),
ModbusFieldConfig( # A05.Pumpe HKR 3
name="a05_pumpe_hkr_3",
address=33284,
unit="%",
device_class="power_factor",
state_class="measurement",
multiplier=0.01,
),
ModbusFieldConfig( # A12.Brennerstatus
name="a12_brennerstatus",
Expand Down Expand Up @@ -259,8 +272,30 @@ class ModbusFieldConfig:
input_type=2,
range_data=(5, 75),
),
ModbusFieldConfig( # HKR1 Absenktemperatur Nacht
name="hkr1_absenktemperatur_nacht",

ModbusFieldConfig( # HKR1 Vorlaufart
name="hkr1_vorlaufart",
address=2819,
unit="",
device_class=None,
state_class=None,
register=2,
multiplier=1,
data=("0", "1"),
),
ModbusFieldConfig( # HKR1 Fix Vorlauf Tag
name="hkr1_fix_vorlauf_tag",
address=2820,
unit="°C",
device_class="temperature",
state_class="measurement",
register=2,
multiplier=1,
edit=True,
data=(5, 75),
),
ModbusFieldConfig( # HKR1 Fix Vorlauf Nacht
name="hkr1_fix_vorlauf_nacht",
address=2821,
unit="°C",
device_class="temperature",
Expand All @@ -271,8 +306,8 @@ class ModbusFieldConfig:
input_type=2,
range_data=(5, 75),
),
ModbusFieldConfig( # HKR1 Heizkurve Tag Temp. 1
name="hkr1_heizkurve_temp_tag_1",
ModbusFieldConfig( # HKR1 Kurve Solltemperatur Tag1
name="hkr1_kurve_solltemperatur_tag1",
address=2822,
unit="°C",
device_class="temperature",
Expand Down Expand Up @@ -367,6 +402,17 @@ class ModbusFieldConfig:
range_data=(5, 75),
conf_option=1,
),
ModbusFieldConfig( # HKR2 Vorlaufart
name="hkr2_vorlaufart",
address=3075,
unit="",
device_class=None,
state_class=None,
register=2,
multiplier=1,
data=("0", "1"),
),

ModbusFieldConfig( # HKR2 Absenktemperatur Nacht
name="hkr2_absenktemperatur_nacht",
address=3077,
Expand Down Expand Up @@ -457,6 +503,7 @@ class ModbusFieldConfig:
range_data=(0, 40),
conf_option=1,
),

ModbusFieldConfig( # HKR3 Betriebsart
name="hkr3_betriebsart",
address=3330,
Expand All @@ -482,8 +529,33 @@ class ModbusFieldConfig:
range_data=(5, 75),
conf_option=2,
),
ModbusFieldConfig( # HKR3 Absenktemperatur Nacht
name="hkr3_absenktemperatur_nacht",

ModbusFieldConfig( # HKR3 Vorlaufart
name="hkr3_vorlaufart",
address=3331,
unit="",
device_class=None,
state_class=None,
register=2,
multiplier=1,
data=("0", "1"),
),


ModbusFieldConfig( # HKR3 Fix Vorlauf Tag
name="hkr3_fix_vorlauf_tag",
address=3332,
unit="°C",
device_class="temperature",
state_class="measurement",
register=2,
multiplier=1,
edit=True,
data=(5, 75),
),

ModbusFieldConfig( # HKR3 Fix Vorlauf Nacht
name="hkr3_fix_vorlauf_nacht",
address=3333,
unit="°C",
device_class="temperature",
Expand Down Expand Up @@ -572,6 +644,7 @@ class ModbusFieldConfig:
range_data=(0, 40),
conf_option=2,
),

ModbusFieldConfig( # DigIn Stoerungen
name="digin_stoerungen",
address=33045,
Expand Down Expand Up @@ -632,9 +705,9 @@ class ModbusFieldConfig:
ModbusFieldConfig( # elektrische Wärmepumenleistung
name="elek_waermepumpe_leistung",
address=33545,
unit="kW",
device_class="power",
state_class="measurement",
unit="kWh",
device_class="energy",
state_class="total",
register=2,
edit=False,
conf_option=4,
Expand Down
2 changes: 1 addition & 1 deletion custom_components/solvis_control/strings.json
Original file line number Diff line number Diff line change
Expand Up @@ -268,4 +268,4 @@
}
}
}
}
}
2 changes: 1 addition & 1 deletion custom_components/solvis_control/translations/de.json
Original file line number Diff line number Diff line change
Expand Up @@ -268,4 +268,4 @@
}
}
}
}
}
Loading