Expand Up @@ -619,7 +619,7 @@ \subsubsection{Outputs}\label{outputs-039}

\paragraph{VRF Heat Pump Total Heating Rate {[}W{]}}\label{vrf-heat-pump-total-heating-rate-w}

This output field is the operating total heating capacity of the variable refrigerant flow heat pump in Watts. The capacity includes any degradation due to defrost mode. This value is calculated for each HVAC system time step being simulated, and the results are averaged for the time step being reported. This value should match the sum of the individual zone terminal unit heating coil output variables for Heating Coil Heating Rate.
This output field is the operating total heating capacity of the variable refrigerant flow heat pump in Watts. The capacity includes any degradation due to defrost mode. This value is calculated for each HVAC system time step being simulated, and the results are averaged for the time step being reported. This value should match the sum of the individual zone terminal unit heating coil output variables for Heating Coil Heating Rate plus any piping loss.

\paragraph{VRF Heat Pump Cooling Electricity Rate {[}W{]}}\label{vrf-heat-pump-cooling-electric-power-w}

Expand Down Expand Up @@ -1155,7 +1155,7 @@ \subsubsection{Outputs}

\paragraph{VRF Heat Pump Total Heating Rate {[}W{]}}\label{vrf-heat-pump-total-heating-rate-w-fluidTCtrl}

This output field is the operating total heating capacity of the variable refrigerant flow heat pump in Watts. The capacity includes any degradation due to defrost mode. This value is calculated for each HVAC system time step being simulated, and the results are averaged for the time step being reported. This value should match the sum of the individual zone terminal unit heating coil output variables for Heating Coil Heating Rate.
This output field is the operating total heating capacity of the variable refrigerant flow heat pump in Watts. The capacity includes any degradation due to defrost mode. This value is calculated for each HVAC system time step being simulated, and the results are averaged for the time step being reported. This value should match the sum of the individual zone terminal unit heating coil output variables for Heating Coil Heating Rate plus any piping loss.

\paragraph{VRF Heat Pump Compressor Rotating Speed {[}rev/min{]}}\label{vrf-heat-pump-compressor-rotating-speed-revmin}

Expand Down

5 comments on commit 6379fdc

@nrel-bot
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

fixDocVRFheatpumpHeatRate (Unknown) - Win64-Windows-10-VisualStudio-16: OK (2862 of 2862 tests passed, 0 test warnings)

Build Badge Test Badge

@nrel-bot-3
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

fixDocVRFheatpumpHeatRate (Unknown) - x86_64-MacOS-10.18-clang-15.0.0: Tests Failed (1469 of 3654 tests passed, 446 test warnings)

Messages:\n

  • 589 tests had: AUD diffs.
  • 560 tests had: EIO diffs.
  • 282 tests had: RDD diffs.
  • 121 tests had: Table small diffs.
  • 146 tests had: Table big diffs.
  • 26 tests had: ERR diffs.
  • 29 tests had: Table string diffs.
  • 7 tests had: ESO small diffs.
  • 7 tests had: MTR small diffs.
  • 14 tests had: ESO big diffs.
  • 10 tests had: MTR big diffs.
  • 1 test had: MTD diffs.
  • 1 test had: IDF diffs.

Failures:\n

integration Test Summary

  • Passed: 789
  • Failed: 5

regression Test Summary

  • Passed: 640
  • Failed: 151

Build Badge Test Badge

@nrel-bot-2b
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

fixDocVRFheatpumpHeatRate (Unknown) - x86_64-Linux-Ubuntu-22.04-gcc-11.4: OK (3546 of 3695 tests passed, 449 test warnings)

Messages:\n

  • 593 tests had: AUD diffs.
  • 564 tests had: EIO diffs.
  • 283 tests had: RDD diffs.
  • 121 tests had: Table small diffs.
  • 147 tests had: Table big diffs.
  • 26 tests had: ERR diffs.
  • 30 tests had: Table string diffs.
  • 7 tests had: ESO small diffs.
  • 7 tests had: MTR small diffs.
  • 14 tests had: ESO big diffs.
  • 10 tests had: MTR big diffs.
  • 1 test had: MTD diffs.
  • 1 test had: IDF diffs.

Failures:\n

regression Test Summary

  • Passed: 662
  • Failed: 149

Build Badge Test Badge

@nrel-bot-2c
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

fixDocVRFheatpumpHeatRate (Unknown) - x86_64-Linux-Ubuntu-22.04-gcc-11.4-UnitTestsCoverage-Debug: OK (2070 of 2070 tests passed, 0 test warnings)

Build Badge Test Badge Coverage Badge

@nrel-bot-2b
Copy link

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

fixDocVRFheatpumpHeatRate (Unknown) - x86_64-Linux-Ubuntu-22.04-gcc-11.4-IntegrationCoverage-Debug: OK (795 of 795 tests passed, 0 test warnings)

Build Badge Test Badge Coverage Badge

Please sign in to comment.