Correct reference entering air temperatures for the water to air heat pump dataset #10852

Open
wants to merge 1 commit into
base: develop
Choose a base branch
from
Open
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
12 changes: 6 additions & 6 deletions datasets/WaterToAirHeatPumps.idf
Original file line number Diff line number Diff line change
Expand Up @@ -9,8 +9,8 @@
!- Rated characteristics:
!- * Cooling capacity: 69 kBtu/h at 86F entering water temperature, and 80.6F/66.2F entering air dry-bulb and wet-bulb
!- * Cooling efficiency: 13.3 EER at 86F entering water temperature, and 80.6F/66.2F entering air dry-bulb and wet-bulb
!- * Heating capacity: 92.5 kBtu/h at 68F entering water temperature, and 80.6F/66.2F entering air dry-bulb and wet-bulb
!- * Heating efficiency: 5.0 COP at 68F entering water temperature, and 80.6F/66.2F entering air dry-bulb and wet-bulb
!- * Heating capacity: 92.5 kBtu/h at 68F entering water temperature, and 68F/59F entering air dry-bulb and wet-bulb
!- * Heating efficiency: 5.0 COP at 68F entering water temperature, and 68F/59F entering air dry-bulb and wet-bulb

Curve:QuadLinear,
TCH072_WLHP_CLG_CAPFT, !- Name
Expand Down Expand Up @@ -131,8 +131,8 @@ Curve:QuadLinear,
!- Rated characteristics:
!- * Cooling capacity: 77.72 kBtu/h at 59F entering water temperature, and 80.6F/66.2F entering air dry-bulb and wet-bulb
!- * Cooling efficiency: 19.37 EER at 59F entering water temperature, and 80.6F/66.2F entering air dry-bulb and wet-bulb
!- * Heating capacity: 73.08 kBtu/h at 50F entering water temperature, and 80.6F/66.2F entering air dry-bulb and wet-bulb
!- * Heating efficiency: 4.3 COP at 50F entering water temperature, and 80.6F/66.2F entering air dry-bulb and wet-bulb
!- * Heating capacity: 73.08 kBtu/h at 50F entering water temperature, and 68F/59F entering air dry-bulb and wet-bulb
!- * Heating efficiency: 4.3 COP at 50F entering water temperature, and 68F/59F entering air dry-bulb and wet-bulb

!- Performance curve based on 15% methanol antifreeze solution
Curve:QuadLinear,
Expand Down Expand Up @@ -258,8 +258,8 @@ Curve:QuadLinear,
!- Rated characteristics:
!- * Cooling capacity: 70.29 kBtu/h at 77F entering water temperature, and 80.6F/66.2F entering air dry-bulb and wet-bulb
!- * Cooling efficiency: 14.35 EER at 77F entering water temperature, and 80.6F/66.2F entering air dry-bulb and wet-bulb
!- * Heating capacity: 56.14 kBtu/h at 32F entering water temperature, and 80.6F/66.2F entering air dry-bulb and wet-bulb
!- * Heating efficiency: 3.42 COP at 32F entering water temperature, and 80.6F/66.2F entering air dry-bulb and wet-bulb
!- * Heating capacity: 56.14 kBtu/h at 32F entering water temperature, and 68F/59F entering air dry-bulb and wet-bulb
!- * Heating efficiency: 3.42 COP at 32F entering water temperature, and 68F/59F entering air dry-bulb and wet-bulb

!- Performance curve based on 15% methanol antifreeze solution
Curve:QuadLinear,
Expand Down