Notifications
You must be signed in to change notification settings - Fork 12
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Add a Mel frequency scale spectrogram to the enum SpectrogramImageType #332
Comments
towsey
added a commit
that referenced
this issue
Jul 30, 2020
Issue #332 Set up basic structure for including mel-scale and octave-scale spectrograms in the type of generated standard scale spectrograms..
towsey
added a commit
that referenced
this issue
Jul 30, 2020
Issue #332 There was a limited number of colours to use as tags for different spectrogram types. By adding two new spectrograms, there was an insufficient number of colours. Changed the colour palette.
towsey
added a commit
that referenced
this issue
Jul 30, 2020
Issue #332 Get Mel frequency scale spectrograms working. Start work on Octave scale spectrograms.
towsey
added a commit
that referenced
this issue
Jul 31, 2020
Issue #332 Get Octave spectrograms going.
towsey
added a commit
that referenced
this issue
Aug 2, 2020
towsey
added a commit
that referenced
this issue
Aug 3, 2020
towsey
added a commit
that referenced
this issue
Aug 4, 2020
Issue #332 Change names of hte main frequency scale types and remove old methods that used to do tests.
towsey
added a commit
that referenced
this issue
Aug 4, 2020
Issue #332 Shift methods to do with Mel scale to the SpectrogramMelScale class.
towsey
added a commit
that referenced
this issue
Aug 4, 2020
towsey
added a commit
that referenced
this issue
Aug 4, 2020
Issue #332 Add tests and rework existing tests for frequency scales
towsey
added a commit
that referenced
this issue
Aug 5, 2020
Issue #332 Also have one change required in IndexCalculateTests. This may cause the test to fail.
towsey
added a commit
that referenced
this issue
Aug 6, 2020
towsey
added a commit
that referenced
this issue
Aug 6, 2020
towsey
added a commit
that referenced
this issue
Aug 6, 2020
towsey
added a commit
that referenced
this issue
Aug 11, 2020
towsey
added a commit
that referenced
this issue
Aug 11, 2020
Issue #332 This will create conflict in another brnach. Easy to fix. Accept Hanning as default window.
towsey
added a commit
that referenced
this issue
Aug 11, 2020
Issue #332 Add another constructor which accepts FreqScale as argument
towsey
added a commit
that referenced
this issue
Aug 11, 2020
towsey
added a commit
that referenced
this issue
Aug 11, 2020
towsey
added a commit
that referenced
this issue
Aug 12, 2020
Issue #332 Also need to add a new test for calculating grid locations and fix other tests.
towsey
added a commit
that referenced
this issue
Aug 13, 2020
towsey
added a commit
that referenced
this issue
Aug 13, 2020
towsey
added a commit
that referenced
this issue
Aug 13, 2020
Issue #332 Previously calculated an octave scale that was once used for a high SR marine recording. Now implement an octave scale that is used for spectral data reduction. This will be used subsequently for content description.
towsey
added a commit
that referenced
this issue
Aug 17, 2020
Issue #332 In some cases, log being calculated without catching zeros. Incorporate e;silon into log transform.
towsey
added a commit
that referenced
this issue
Aug 17, 2020
towsey
added a commit
that referenced
this issue
Aug 17, 2020
towsey
added a commit
that referenced
this issue
Aug 19, 2020
towsey
added a commit
that referenced
this issue
Aug 19, 2020
towsey
added a commit
that referenced
this issue
Aug 19, 2020
Issue #332 Add in new methods for rescaling frequency but keeping linear.
towsey
added a commit
that referenced
this issue
Aug 19, 2020
towsey
added a commit
that referenced
this issue
Aug 19, 2020
Issue #332 Finalise test for conversion of amplitude to octave frequency scale
towsey
added a commit
that referenced
this issue
Aug 20, 2020
Issue #332 Shift filterBank methods to Spectrum tools because they are now generalised for all frequency scale transformations.
towsey
added a commit
that referenced
this issue
Aug 20, 2020
Issue #332 Now that have ability to visualise a data reduced spectrogram, I changed it to give better distribution of filterbanks.
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
I would like to add another spectrogram type to those currently available, namely a gray scale spectrogram having Mel frequency scale.
We already produce the data for this spectrogram in order to produce the MFCC spectrogram, but currently the Mel scale version is not available. It will be useful since some recognizers for low frequency sounds, ie trucks planes etc may work better with shift to Mel scale.
Describe the solution you'd like
Add Mel scale spectrogram to the enum and to the config file etc.
The text was updated successfully, but these errors were encountered: