Expand Up @@ -151,15 +151,16 @@ The default baud rate is 9600 (users can set by themselves),
1 bit of stop,
no parity RS485 communication

Serial command
| Description READ
| Trigger a temperature and humidity report (27.4℃, 67.7% temperature 27.4℃ humidity 67.7%) AUTO
| Start the automatic temperature and humidity report function (Same as above) STOP
| Stop the automatic reporting of temperature and humidity BR:XXXX
| Set the baud rate 9600~19200 (BR: 9600 baud rate is 9600) TC:XX.X
| Set temperature calibration (-10.0~10.0) (TC:02.0 temperature correction value is 2.0℃) HC:XX.X
| Set humidity calibration (-10.0~10.0) (HC:-05.1 Humidity correction value is -5.1%) HZ:XXX
| Set the temperature and humidity report rate (0.5,1,2,5,10) (HZ: 2 automatic reporting rate 2Hz) PARAM
| Read current system settings,

PARAM instruction: TC:0.0,HC:0.0,BR:9600,HZ:1 ->Temperature correction value 0.0 Humidity correction value 0.0 Baud rate 9600 Report rate 1Hz SLAVE_ADD:1 ->MODBUS slave address 0x01
| Serial command | Description |
| -------------- | ------------------------------------------------------------------------------------------------ |
| READ | Trigger a temperature and humidity report (27.4℃, 67.7% temperature 27.4℃ humidity 67.7%) |
| AUTO | Start the automatic temperature and humidity report function (Same as above) |
| STOP | Stop the automatic reporting of temperature and humidity |
| BR:XXXX | Set the baud rate 9600~19200 (BR: 9600 baud rate is 9600) |
| TC:XX.X | Set temperature calibration (-10.0~10.0) (TC:02.0 temperature correction value is 2.0℃) |
| HC:XX.X | Set humidity calibration (-10.0~10.0) (HC:-05.1 Humidity correction value is -5.1%) |
| HZ:XXX | Set the temperature and humidity report rate (0.5,1,2,5,10) (HZ: 2 automatic reporting rate 2Hz) |
| PARAM | Read current system settings, |

PARAM instruction:
TC:0.0,HC:0.0,BR:9600,HZ:1 -> Temperature correction value 0.0 Humidity correction value 0.0 Baud rate 9600 Report rate 1Hz SLAVE_ADD:1 ->MODBUS slave address 0x01