5 changes: 5 additions & 0 deletions drivers/SmartThings/zigbee-humidity-sensor/fingerprints.yml
Original file line number Diff line number Diff line change
Expand Up @@ -58,6 +58,11 @@ zigbeeManufacturer:
manufacturer: HEIMAN
model: HT-EF-3.0
deviceProfileName: humidity-temp-battery
- id: frient/AQSZB-110
deviceLabel: Air Quality Sensor
manufacturer: frient A/S
model: AQSZB-110
deviceProfileName: frient-airquality-humidity-temperature-battery
- id: frient/HMSZB-110
deviceLabel: frient Humidity Sensor
manufacturer: frient A/S
Expand Down
Original file line number Diff line number Diff line change
@@ -0,0 +1,52 @@
name: frient-airquality-humidity-temperature-battery
components:
- id: main
capabilities:
- id: airQualitySensor
version: 1
- id: tvocMeasurement
version: 1
- id: tvocHealthConcern
version: 1
config:
values:
- key: "tvocHealthConcern.value"
enabledValues:
- good
- moderate
- slightlyUnhealthy
- unhealthy
- veryUnhealthy
- id: relativeHumidityMeasurement
version: 1
- id: temperatureMeasurement
version: 1
- id: battery
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
preferences:
- preferenceId: humidityOffset
explicit: true
- title: "Humidity Sensitivity (%)"
name: humiditySensitivity
description: "Minimum change in humidity level to report"
required: false
preferenceType: number
definition:
minimum: 1
maximum: 50
default: 3
- preferenceId: tempOffset
explicit: true
- title: "Temperature Sensitivity (°)"
name: temperatureSensitivity
description: "Minimum change in temperature to report"
required: false
preferenceType: number
definition:
minimum: 0.1
maximum: 2.0
default: 1.0
Original file line number Diff line number Diff line change
Expand Up @@ -23,7 +23,8 @@ local devices = {
FRIENT_HUMIDITY_TEMP_SENSOR = {
FINGERPRINTS = {
{ mfr = "frient A/S", model = "HMSZB-110" },
{ mfr = "frient A/S", model = "HMSZB-120" }
{ mfr = "frient A/S", model = "HMSZB-120" },
{ mfr = "frient A/S", model = "AQSZB-110" }
},
CONFIGURATION = {
{
Expand Down
Original file line number Diff line number Diff line change
@@ -0,0 +1,165 @@
local capabilities = require "st.capabilities"
local util = require "st.utils"
local log = require "log"
local data_types = require "st.zigbee.data_types"
local zcl_clusters = require "st.zigbee.zcl.clusters"
local TemperatureMeasurement = zcl_clusters.TemperatureMeasurement
local HumidityMeasurement = zcl_clusters.RelativeHumidity
local PowerConfiguration = zcl_clusters.PowerConfiguration
local device_management = require "st.zigbee.device_management"
local cluster_base = require "st.zigbee.cluster_base"
local battery_defaults = require "st.zigbee.defaults.battery_defaults"
local configurationMap = require "configurations"

local FRIENT_AIR_QUALITY_SENSOR_FINGERPRINTS = {
{ mfr = "frient A/S", model = "AQSZB-110", subdriver = "airquality" }
}

local function can_handle_frient(opts, driver, device, ...)
for _, fingerprint in ipairs(FRIENT_AIR_QUALITY_SENSOR_FINGERPRINTS) do
if device:get_manufacturer() == fingerprint.mfr and device:get_model() == fingerprint.model and fingerprint.subdriver == "airquality" then
return true
end
end
return false
end

local Frient_VOCMeasurement = {
ID = 0xFC03,
ManufacturerSpecificCode = 0x1015,
attributes = {
MeasuredValue = { ID = 0x0000, base_type = data_types.Uint16 },
MinMeasuredValue = { ID = 0x0001, base_type = data_types.Uint16 },
MaxMeasuredValue = { ID = 0x0002, base_type = data_types.Uint16 },
Resolution = { ID = 0x0003, base_type = data_types.Uint16 },
},
}

Frient_VOCMeasurement.attributes.MeasuredValue._cluster = Frient_VOCMeasurement
Frient_VOCMeasurement.attributes.MinMeasuredValue._cluster = Frient_VOCMeasurement
Frient_VOCMeasurement.attributes.MaxMeasuredValue._cluster = Frient_VOCMeasurement
Frient_VOCMeasurement.attributes.Resolution._cluster = Frient_VOCMeasurement

local MAX_VOC_REPORTABLE_VALUE = 5500 -- Max VOC reportable value

--- Table to map VOC (ppb) to HealthConcern
local VOC_TO_HEALTHCONCERN_MAPPING = {
[2201] = "veryUnhealthy",
[661] = "unhealthy",
[221] = "slightlyUnhealthy",
[66] = "moderate",
[0] = "good",
}

--- Map VOC (ppb) to HealthConcern
local function voc_to_healthconcern(raw_voc)
for voc, perc in util.rkeys(VOC_TO_HEALTHCONCERN_MAPPING) do
if raw_voc >= voc then
return perc
end
end
end
--- Map VOC (ppb) to CAQI
local function voc_to_caqi(raw_voc)
if (raw_voc > 5500) then
return 100
else
return math.floor(raw_voc*99/5500)
end
end

-- May take around 8 minutes for the first valid VOC measurement to be reported after the device is powered on
local function voc_measure_value_attr_handler(driver, device, attr_val, zb_rx)
local voc_value = attr_val.value
if (voc_value < 65535) then -- ignore it if it's outside the limits
log.trace("Received VOC MeasuredValue :"..util.stringify_table(voc_value))
voc_value = util.clamp_value(voc_value, 0, MAX_VOC_REPORTABLE_VALUE)
device:emit_event(capabilities.airQualitySensor.airQuality({ value = voc_to_caqi(voc_value)}))
device:emit_event(capabilities.tvocHealthConcern.tvocHealthConcern(voc_to_healthconcern(voc_value)))
device:emit_event(capabilities.tvocMeasurement.tvocLevel({ value = voc_value, unit = "ppb" }))
else
log.warn("Ignoring invalid VOC MeasuredValue : "..util.stringify_table(voc_value))
end
end

-- The device sends the value of MeasuredValue to be 0x8000, which corresponds to -327.68C, until it gets the first valid measurement. Therefore we don't emit event before the value is correct. It may take up to 4 minutes
local function temperatureHandler(driver, device, attr_val, zb_rx)
local temp_value = attr_val.value
if (temp_value > -32768) then
log.debug("Received Temperature MeasuredValue :"..util.stringify_table(temp_value))
device:emit_event(capabilities.temperatureMeasurement.temperature({ value = temp_value / 100, unit = "C" }))
else
log.warn("Ignoring invalid Temperature MeasuredValue : "..util.stringify_table(temp_value))
end
end

local function device_init(driver, device)
log.trace "Initializing sensor"
battery_defaults.build_linear_voltage_init(2.3, 3.0)(driver, device)
local configuration = configurationMap.get_device_configuration(device)
if configuration ~= nil then
for _, attribute in ipairs(configuration) do
device:add_configured_attribute(attribute)
end
end
end

local function device_added(driver, device)
device:emit_event(capabilities.airQualitySensor.airQuality(voc_to_caqi(0)))
device:emit_event(capabilities.tvocHealthConcern.tvocHealthConcern(voc_to_healthconcern(0)))
device:emit_event(capabilities.tvocMeasurement.tvocLevel({ value = 0, unit = "ppb" }))
end

local function do_refresh(driver, device)
log.trace "Refreshing sensor attributes"
for _, fingerprint in ipairs(FRIENT_AIR_QUALITY_SENSOR_FINGERPRINTS) do
if device:get_manufacturer() == fingerprint.mfr and device:get_model() == fingerprint.model then
device:send(cluster_base.read_manufacturer_specific_attribute(device, Frient_VOCMeasurement.ID, Frient_VOCMeasurement.attributes.MeasuredValue.ID, Frient_VOCMeasurement.ManufacturerSpecificCode):to_endpoint(0x26))
device:send(TemperatureMeasurement.attributes.MeasuredValue:read(device):to_endpoint(0x26))
device:send(HumidityMeasurement.attributes.MeasuredValue:read(device):to_endpoint(0x26))
device:send(PowerConfiguration.attributes.BatteryVoltage:read(device))
end
end
end

local function do_configure(driver, device)
device:configure()
device:send(device_management.build_bind_request(device, Frient_VOCMeasurement.ID, driver.environment_info.hub_zigbee_eui, 0x26))

device:send(
cluster_base.configure_reporting(
device,
data_types.ClusterId(Frient_VOCMeasurement.ID),
Frient_VOCMeasurement.attributes.MeasuredValue.ID,
Frient_VOCMeasurement.attributes.MeasuredValue.base_type.ID,
60, 600, 10
):to_endpoint(0x26)
)

device.thread:call_with_delay(5, function()
do_refresh(driver, device)
end)
end

local frient_airquality_sensor = {
NAME = "frient Air Quality Sensor",
lifecycle_handlers = {
init = device_init,
added = device_added,
doConfigure = do_configure,
},
zigbee_handlers = {
cluster = {},
attr = {
[Frient_VOCMeasurement.ID] = {
[Frient_VOCMeasurement.attributes.MeasuredValue.ID] = voc_measure_value_attr_handler,
},
[TemperatureMeasurement.ID] = {
[TemperatureMeasurement.attributes.MeasuredValue.ID] = temperatureHandler,
},
}
},
can_handle = can_handle_frient
}

return frient_airquality_sensor
Original file line number Diff line number Diff line change
Expand Up @@ -20,7 +20,8 @@ local TemperatureMeasurement = zcl_clusters.TemperatureMeasurement

local FRIENT_TEMP_HUMUDITY_SENSOR_FINGERPRINTS = {
{ mfr = "frient A/S", model = "HMSZB-110" },
{ mfr = "frient A/S", model = "HMSZB-120" }
{ mfr = "frient A/S", model = "HMSZB-120" },
{ mfr = "frient A/S", model = "AQSZB-110" }
}

local function can_handle_frient_sensor(opts, driver, device)
Expand Down Expand Up @@ -73,6 +74,9 @@ local frient_sensor = {
doConfigure = do_configure,
infoChanged = info_changed
},
sub_drivers = {
require("frient-sensor/air-quality")
},
can_handle = can_handle_frient_sensor
}

Expand Down
Loading