Skip to content

Commit

Permalink
Merge pull request #393 from frsantos/update_kstar_defintion
Browse files Browse the repository at this point in the history
KSTAR: Reorganise registers into blocks of 125
  • Loading branch information
StephanJoubert authored Sep 10, 2023
2 parents 19b75d6 + fe261dd commit b107eed
Showing 1 changed file with 22 additions and 19 deletions.
41 changes: 22 additions & 19 deletions custom_components/solarman/inverter_definitions/kstar_hybrid.yaml
Original file line number Diff line number Diff line change
@@ -1,37 +1,40 @@
# KSTAR Hybrid Inverter
# Modbus information taken from "MODBUS RS485 Communication Protocol V2.5" document provided by KSTAR

#INPUT_REGISTERS = 3000 - 3660 # 0x0BB8 - 0x0E4C
#HOLDING_REGISTERS = 3200 - 3237 # 0x0C80 - 0x0C9B
# This inverter exposes its data in the following registers (although not all of them are used by this definition file):
#
# - INPUT_REGISTERS 3000 - 3660 decimal, 0x0BB8 - 0x0E4C hexadecimal
# - HOLDING_REGISTERS 3200 - 3237 decimal. 0x0C80 - 0x0C9B hexadecimal
#
# Each request can get a maximum of 125 registers as per modbus protocol (start and end included), so we need to
# split up the list of used registers into multiple requests of maximum 125 registers each.

requests:
# Input registers 3000 - 3667
# Start requesting from the first needed register (3000)
- start: 3000
end: 3125
end: 3124
mb_functioncode: 0x04

# Input registers 3200 - 3228 not read as they would clash with holding registers
# Input registers 3200 - 3227 can't be read as they would clash with holding registers of same number
- start: 3125
end: 3200
end: 3199
mb_functioncode: 0x04

# Change to holding registers 3200 - 3237 (mb_functioncode 3) for the inverter system information.
- start: 3200
end: 3217
mb_functioncode: 0x03

# Continue with the needed input registers
- start: 3228
end: 3250
end: 3249
mb_functioncode: 0x04

# Last input register currently used by this definition file is 3301, so we can skip the rest for now.
- start: 3250
end: 3375
mb_functioncode: 0x04

- start: 3375
end: 3500
end: 3301
mb_functioncode: 0x04

# Holding registers 3200 - 3237. Inverter system information.
- start: 3200
end: 3218
mb_functioncode: 0x03

parameters:
- group: solar
items:
Expand Down Expand Up @@ -699,7 +702,7 @@ parameters:
scale: 0.01
rule: 1
registers: [ 3098 ]
icon: 'mdi:home-lightning-bolt'
icon: 'mdi:sine-wave'

- name: "R-phase Meter Current"
class: "current"
Expand Down Expand Up @@ -744,7 +747,7 @@ parameters:
scale: 0.01
rule: 1
registers: [ 3125 ]
icon: 'mdi:home-lightning-bolt'
icon: 'mdi:sine-wave'

- name: "R-phase Inverter Power"
class: "power"
Expand Down

0 comments on commit b107eed

Please sign in to comment.