18 changes: 11 additions & 7 deletions src/apl/tasks/task_PowerControl.c
Original file line number Diff line number Diff line change
Expand Up @@ -45,15 +45,15 @@ volatile uint16_t exec_PowerControl(void) {

volatile uint16_t fres = 1;


//------------------------------------------------------
// Both converters are supplied by the same power input and c4swbb_1 is the
// instance sampling the input voltage. Once this voltage is within the nominal
// operating range, the POWER_SOURCE_DETECTED flag is set
//
// Please note:
// This test is for startup only. There is no hysteresis and no shut-down event
// is triggered. This flag only provides an immediate indication. Power Supply
// Over/Under Voltage Lock Out are taken care of by the fault handler.
// is triggered. This flag only provides an immediate indication for the state machine.
// Board Over/Under Voltage Lock Out are managed by the fault handler.

if((C4SWBB_VIN_UVLO < c4swbb_1.data.v_in) && (c4swbb_1.data.v_in < C4SWBB_VIN_OVLO)) {
c4swbb_1.status.bits.power_source_detected = true;
Expand All @@ -64,15 +64,19 @@ volatile uint16_t exec_PowerControl(void) {
c4swbb_2.status.bits.power_source_detected = false;
}

//------------------------------------------------------
// The power supply fault flag is only reset if ALL fault objects have been cleared
// The fault handler does not consider cross-dependencies of individual faults.
// These need to be tied together in this state machine.
//
// Please note:
// Output Over Current conditions are allowed and will result in a hard limitation
// of the output current at the defined level. Thus over current conditions will NOT
// lead to an automatic shut down of the converter.

// ToDo: RegulationError is very sensitive to changes to VREF.
// Further testing is required to enable this feature.
// lead to an automatic shut down of the converter. The shut down event is triggered
// when output voltage drops due to current limiting conditions. This is detected by
// the fltobj_RegulationError_USB_x objects comparing output voltage against output
// voltage reference. The fault trigger is defined by VOUT_MAX_DEVIATION in file
// 'syscfg_limits.h'

fltobj_RegulationError_USBPort_1.status.bits.fltchken = (volatile bool)(c4swbb_1.status.bits.op_status == CONVERTER_STATE_COMPLETE);
if (!fltobj_RegulationError_USBPort_1.status.bits.fltchken) fltobj_RegulationError_USBPort_1.status.bits.fltstat = false;