change the format of lammps thermo from %.8g (lammps default, 8 significant figures) to %20.6f for concerned thermal quantities.
some systems have very large per-atom energy (lower than -1000 eV/atom) While the reference point of the energy could be arbitary that gives even lower values, the deltaE in cared range of thermal conditions is fixed e.g. ~ several meV/atom. Storing the total energy of such systems may run out of significant figures before the cared precision.
formats of related data-duplication output files 'data' are also changed from %.6e to %20.6f format of ti.out is also changed from %.8e in to %.12e which stores total energy too