FDS User Guide: Add || to Eq 10.8 for leak area #12208

Merged
merged 1 commit into from
Nov 1, 2023
Merged
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
2 changes: 1 addition & 1 deletion Manuals/FDS_User_Guide/FDS_User_Guide.tex
Original file line number Diff line number Diff line change
Expand Up @@ -3858,7 +3858,7 @@ \subsubsection{Pressure Zone Leakage}

As the interior pressure rises in a typical building, the leakage area grows as small gaps, cracks, and other leakage paths open up. Leakage tests performed according to test standards such as ASTM~E779 provide two additional data points to quantify this behavior. These are the {\ct LEAK\_PRESSURE\_EXPONENT} and the {\ct LEAK\_REFERENCE\_PRESSURE}. The use of these additional inputs are shown in the equation below as $n$ and $\Delta p_{\rm ref}$ respectively where $A_{\rm L,ref}$ is given by {\ct LEAK\_AREA}.
\be
A_{\rm L} = A_{\rm L,ref} \left( \frac{\Delta p}{\Delta p_{\rm ref}} \right)^{n-0.5} \label{leak_formula_2}
A_{\rm L} = A_{\rm L,ref} \left( \frac{\left| \Delta p \right|}{\Delta p_{\rm ref}} \right)^{n-0.5} \label{leak_formula_2}
\ee
By default, $n=0.5$ and $\Delta p_{\rm ref}=4$~Pa, meaning that the leak area will not change with pressure unless you specify an exponent other than 0.5. The {\ct DISCHARGE\_COEFFICIENT} is 1 by default.