% READSYNCWRITE Example file executing read and sync write functions for 1 | ||
% or more Dynamixel motors under Protocol 1.0 communication | ||
% | ||
% Depending on the example code, the motor(s) need to be pre-set to joint | ||
% or wheel mode via the Dynamixel Wizard or equivalent software | ||
% | ||
% Part of the Dynamixel library for Matlab and Simulink | ||
% Author: Georgios Andrikopoulos (geoand@kth.se), 2022 | ||
% Mechatronics & Embedded Control Systems Unit, KTH, Stockholm | ||
|
||
clear | ||
close all | ||
clc | ||
|
||
% Set COM port | ||
com_port = 'COM8'; | ||
|
||
% Set baudrate | ||
baud_rate = 1000000; | ||
|
||
% Set protocol Version | ||
protocol_version = 1; | ||
|
||
% Initialize library and port number | ||
[lib_name, port_num] = initDxl(com_port); | ||
|
||
% Open port | ||
openPortDxl(lib_name, port_num); | ||
|
||
% Set Baudrate | ||
setBaudDxl(lib_name, port_num, baud_rate); | ||
|
||
% Find dynamixels | ||
[motor_IDs, motor_models] = findDxl(lib_name, port_num, protocol_version); | ||
|
||
% Enable torque | ||
torqueDxl(lib_name, port_num, protocol_version, motor_IDs, ... | ||
motor_models, 'Enable'); | ||
|
||
% Check error | ||
checkErrorDxl(lib_name, port_num, protocol_version) | ||
|
||
% Initialize sync write | ||
group_num_write = initSyncWriteDxl(lib_name, port_num, protocol_version,... | ||
motor_models, ["Goal Position"; "Moving Speed"]); | ||
|
||
%% Joint Mode Example | ||
clc | ||
% Data to write | ||
data = 500; % Example goal position for one motor | ||
% data = [1000 2000]; % Example goal position for two motors | ||
|
||
% Sync write function | ||
tic | ||
syncWriteDxl(lib_name, group_num_write(1), motor_IDs, motor_models, ... | ||
data, 'Goal Position') | ||
toc | ||
|
||
% Read functions | ||
tic | ||
readDxl(lib_name, port_num, protocol_version, motor_IDs, motor_models, ... | ||
'Present Position') | ||
readDxl(lib_name, port_num, protocol_version, motor_IDs, motor_models, ... | ||
'Present Speed') | ||
readDxl(lib_name, port_num, protocol_version, motor_IDs, motor_models, ... | ||
'Present Load') | ||
readDxl(lib_name, port_num, protocol_version, motor_IDs, motor_models, ... | ||
'Present Temperature') | ||
toc | ||
|
||
%% Wheel Mode Example | ||
clc | ||
% Data to write | ||
data = 500; % Example moving speed for one motor | ||
% data = [400 300]; % Example moving speeds for two motors | ||
|
||
% Sync write function | ||
tic | ||
syncWriteDxl(lib_name, group_num_write(2), motor_IDs, motor_models, ... | ||
data, 'Moving Speed') | ||
toc | ||
|
||
% Read functions | ||
tic | ||
readDxl(lib_name, port_num, protocol_version, motor_IDs, motor_models, ... | ||
'Present Position') | ||
readDxl(lib_name, port_num, protocol_version, motor_IDs, motor_models, ... | ||
'Present Speed') | ||
readDxl(lib_name, port_num, protocol_version, motor_IDs, motor_models, ... | ||
'Present Load') | ||
readDxl(lib_name, port_num, protocol_version, motor_IDs, motor_models, ... | ||
'Present Temperature') | ||
toc | ||
%% End Session | ||
clc | ||
|
||
% Disable torque | ||
torqueDxl(lib_name, port_num, protocol_version, motor_IDs, ... | ||
motor_models, 'Disable'); | ||
|
||
% Check error | ||
checkErrorDxl(lib_name, port_num, protocol_version) | ||
|
||
% Close port | ||
closePortDxl(lib_name,port_num); |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,108 @@ | ||
% READWRITE Example file executing read and write functions for 1 or more | ||
% Dynamixel motors under Protocol 1.0 communication | ||
% | ||
% Depending on the example code, the motor(s) need to be pre-set to joint | ||
% or wheel mode via the Dynamixel Wizard or equivalent software | ||
% | ||
% Part of the Dynamixel library for Matlab and Simulink | ||
% Author: Georgios Andrikopoulos (geoand@kth.se), 2022 | ||
% Mechatronics & Embedded Control Systems Unit, KTH, Stockholm | ||
|
||
clear | ||
close all | ||
clc | ||
|
||
% Set COM port | ||
com_port = 'COM8'; | ||
|
||
% Set baudrate | ||
baud_rate = 1000000; | ||
|
||
% Set protocol Version | ||
protocol_version = 1; | ||
|
||
% Initialize library and port number | ||
[lib_name, port_num] = initDxl(com_port); | ||
|
||
% Open port | ||
openPortDxl(lib_name, port_num); | ||
|
||
% Set Baudrate | ||
setBaudDxl(lib_name, port_num, baud_rate); | ||
|
||
% Find dynamixels | ||
[motor_IDs, motor_models] = findDxl(lib_name, port_num, protocol_version); | ||
|
||
% Enable torque | ||
torqueDxl(lib_name, port_num, protocol_version, motor_IDs, ... | ||
motor_models, 'Enable'); | ||
|
||
% Check error | ||
checkErrorDxl(lib_name, port_num, protocol_version) | ||
|
||
%% Joint Mode Example | ||
% AX Motor: Make sure that the motor is set to joint mode before using | ||
% this example | ||
clc | ||
|
||
% Data to write | ||
data = 500; % Example goal position for one motor | ||
% data = [1000 500]; % Example goal position for two motors | ||
|
||
% Write function | ||
tic | ||
writeDxl(lib_name, port_num, protocol_version, motor_IDs, motor_models, ... | ||
data, 'Goal Position') | ||
toc | ||
|
||
% Read functions | ||
tic | ||
readDxl(lib_name, port_num, protocol_version, motor_IDs, motor_models, ... | ||
'Present Position') | ||
readDxl(lib_name, port_num, protocol_version, motor_IDs, motor_models, ... | ||
'Present Speed') | ||
readDxl(lib_name, port_num, protocol_version, motor_IDs, motor_models, ... | ||
'Present Load') | ||
readDxl(lib_name, port_num, protocol_version, motor_IDs, motor_models, ... | ||
'Present Temperature') | ||
toc | ||
|
||
%% Wheel Mode Examples | ||
% AX Motor: Make sure that the motor is set to wheel mode before using | ||
% this example | ||
clc | ||
|
||
% Data to write | ||
data = 300; % Example moving speed for one motor | ||
% data = [500 1000]; % Example moving speeds for two motors | ||
|
||
% Write function | ||
tic | ||
writeDxl(lib_name, port_num, protocol_version, motor_IDs, motor_models, ... | ||
data, 'Moving Speed') | ||
toc | ||
|
||
% Read functions | ||
tic | ||
readDxl(lib_name, port_num, protocol_version, motor_IDs, motor_models, ... | ||
'Present Position') | ||
readDxl(lib_name, port_num, protocol_version, motor_IDs, motor_models, ... | ||
'Present Speed') | ||
readDxl(lib_name, port_num, protocol_version, motor_IDs, motor_models, ... | ||
'Present Load') | ||
readDxl(lib_name, port_num, protocol_version, motor_IDs, motor_models, ... | ||
'Present Temperature') | ||
toc | ||
|
||
%% End Session | ||
clc | ||
|
||
% Disable torque | ||
torqueDxl(lib_name, port_num, protocol_version, motor_IDs, motor_models, ... | ||
'Disable'); | ||
|
||
% Check error | ||
checkErrorDxl(lib_name, port_num, protocol_version) | ||
|
||
% Close port | ||
closePortDxl(lib_name,port_num); |
128 changes: 128 additions & 0 deletions
128
examples/matlab/protocol 2.0/FastSyncReadFastSyncWrite.m
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,128 @@ | ||
% FASTSYNCREADFASTSYNCWRITE Example file executing fast sync read and fast | ||
% sync write functions for 2 Dynamixel motors under Protocol 2.0 | ||
% communication and using indirect addresses. | ||
% | ||
% During the initialization phase, the motor(s) are set to 'Extended | ||
% Position Control' operating mode, while their drive mode is set to | ||
% 'Velocity-based Profile'. | ||
% | ||
% Part of the Dynamixel library for Matlab and Simulink | ||
% Author: Georgios Andrikopoulos (geoand@kth.se), 2022 | ||
% Mechatronics & Embedded Control Systems Unit, KTH, Stockholm | ||
|
||
clear | ||
close all | ||
clc | ||
|
||
% Set COM port | ||
com_port = 'COM8'; | ||
|
||
% Set baudrate | ||
baud_rate = 4000000; | ||
|
||
% Set protocol Version | ||
protocol_version = 2; | ||
|
||
% Initialize library and port number | ||
[lib_name, port_num] = initDxl(com_port); | ||
|
||
% Open port | ||
openPortDxl(lib_name, port_num); | ||
|
||
% Set Baudrate | ||
setBaudDxl(lib_name, port_num, baud_rate); | ||
|
||
% Find dynamixels | ||
[motor_IDs, motor_models] = findDxl(lib_name, port_num, protocol_version); | ||
|
||
% Operating modes | ||
operatingModeDxl(lib_name, port_num, protocol_version, motor_IDs, ... | ||
motor_models, 'Extended Position Control'); | ||
|
||
% Drive modes | ||
driveModeDxl(lib_name, port_num, protocol_version, motor_IDs, ... | ||
motor_models, 'Velocity-based Profile'); | ||
|
||
% Indirect addresses are accessible only when the torque is disabled | ||
torqueDxl(lib_name, port_num, protocol_version, motor_IDs, ... | ||
motor_models, 'Disable'); | ||
|
||
% Define the read and write quantities | ||
select_sync_write = ["Goal Position", "LED"]; | ||
select_sync_read = ["Present Position", "Present Velocity", ... | ||
"Present Current/Load", "Present Temperature"]; | ||
|
||
% Set indirect addresses for sync write | ||
[start_address_write_indirect, data_length_write_indirect] = ... | ||
setIndirectWriteDxl(lib_name, port_num, protocol_version, motor_IDs, ... | ||
motor_models, select_sync_write); | ||
|
||
% Set indirect addresses for fast sync read | ||
start_address_read_indirect = start_address_write_indirect + ... | ||
data_length_write_indirect; | ||
[start_address_read_indirect, data_length_read_indirect] = ... | ||
setIndirectReadDxl(lib_name, port_num, protocol_version, motor_IDs, ... | ||
motor_models, start_address_read_indirect, select_sync_read); | ||
|
||
% Enable torque | ||
torqueDxl(lib_name, port_num, protocol_version, motor_IDs, motor_models, ... | ||
'Enable'); | ||
% Check error | ||
checkErrorDxl(lib_name, port_num, protocol_version) | ||
|
||
% Initialize sync write | ||
group_num_write = initSyncWriteIndirectDxl(lib_name, port_num, protocol_version,... | ||
motor_models, start_address_write_indirect, data_length_write_indirect); | ||
|
||
% Initialize sync read | ||
group_num_read = initSyncReadIndirectDxl(lib_name, port_num, protocol_version,... | ||
motor_models, start_address_read_indirect, data_length_read_indirect); | ||
|
||
% Add parameters for the sync read | ||
syncReadAddParamDxl(lib_name, group_num_read, motor_IDs); | ||
|
||
%% Example | ||
clc | ||
|
||
% Goal positions for 2 motors | ||
goal_positions = [1000 1000]; | ||
|
||
% LED state for 2 motors | ||
LED = [0 0]; | ||
|
||
% Set write properties | ||
data_write = [goal_positions; LED]; | ||
|
||
% Fast sync write to indirect data | ||
tic | ||
fastSyncWriteDxl(lib_name, group_num_write, motor_IDs, motor_models, ... | ||
data_write, select_sync_write) | ||
toc | ||
|
||
% Fast sync read from indirect data | ||
tic | ||
read_data = fastSyncReadDxl(lib_name, group_num_read, motor_IDs, ... | ||
motor_models, select_sync_read, start_address_read_indirect); | ||
toc | ||
|
||
present_positions = read_data(1,:) | ||
present_velocities = read_data(2,:) | ||
present_currents = read_data(3,:) | ||
present_temperatures = read_data(4,:) | ||
|
||
|
||
%% End Session | ||
clc | ||
|
||
% Read clear parameters | ||
syncReadClearParamDxl(lib_name, group_num_read); | ||
|
||
% Disable torque | ||
torqueDxl(lib_name, port_num, protocol_version, motor_IDs, motor_models, ... | ||
'Disable'); | ||
|
||
% Check error | ||
checkErrorDxl(lib_name, port_num, protocol_version) | ||
|
||
% Close port | ||
closePortDxl(lib_name,port_num); |
Oops, something went wrong.