Skip to content

Conversation

@MrD-RC
Copy link
Member

@MrD-RC MrD-RC commented Dec 31, 2024

In older versions of INAV. FEATURE MOTOR_STOP was enabled by default. This is for safety, so motors will not spin unexpectedly. When the feature was changed to a parameter. The default was set to OFF, meaning motors will spin with no throttle. This PR re-establishes the past safety president of having motor stop enabled by default.

@MrD-RC MrD-RC added this to the 8.0 milestone Dec 31, 2024
@MrD-RC MrD-RC merged commit 68ee1bb into master Dec 31, 2024
22 checks passed
@MrD-RC MrD-RC deleted the MrD_Default-motor-stop-to-on branch December 31, 2024 23:05
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant