Skip to content

jnctech/ha-tandem-pump

 
 

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

372 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

Tandem t:slim Pump for Home Assistant

Medical Disclaimer: This integration is for informational and home automation purposes only. It is not a medical device and must not be used to make treatment decisions. Always refer to your pump, CGM receiver, or a fingerstick blood glucose meter before acting on any glucose reading or insulin value. For reliable real-time glucose monitoring, use your Dexcom/Libre receiver or compatible CGM app — this integration relies on cloud uploads which can be delayed by minutes to hours. If in doubt, use a fingerstick meter. This software is provided as-is with no warranty. See LICENSE.

The only Home Assistant integration for the Tandem t:slim X2 insulin pump. Get CGM readings, insulin on board, Control-IQ status, and 69 sensors — using your existing Tandem Source account. No extra hardware required.

release HACS Custom build Reliability Security Maintainability Coverage Duplicated Lines License

Add to HACS


What you can do

  • Display your current glucose reading and trend arrow on any Home Assistant dashboard
  • Automate alerts: notify when cartridge insulin drops below 20 u, page family when the pump is suspended
  • Track time-in-range, GMI, and long-term insulin trends over weeks with the Statistics Graph card
  • Know your active basal profile, Control-IQ mode, and IOB — everything your pump reports, visible in your smart home

69 sensors across 7 categories

Category Sensors Highlights
Glucose Monitoring 12 CGM mg/dL + mmol/L, rate of change, TIR, GMI, SD, CV, predicted glucose (PLGS)
Insulin Delivery 14 IOB, basal rate, last bolus, TDI, daily totals, carbs, bolus calculator details, estimated remaining insulin
Pump Battery 4 Battery %, voltage (mV), remaining capacity (mAh), charging status
Alerts & Alarms 3 Last alert, last alarm, active alert count
Pump Status 10 Control-IQ mode, activity mode, cartridge insulin, CGM sensor type, suspend reason, site/cartridge/tubing age
Pump Settings 11 Active profile + hourly schedule, max bolus, CIQ limits, alert thresholds
Device & Timestamps 7 Serial, firmware, last sync, last glucose update
Full sensor list

Glucose Monitoring (12)

Sensor Description
Last glucose (mmol/L) Latest CGM reading in mmol/L
Last glucose (mg/dL) Latest CGM reading in mg/dL
Glucose delta Change since previous reading
CGM rate of change Rate of glucose change (mg/dL/min)
CGM status Sensor signal quality (Normal / High / Low)
Average glucose (mmol/L) Daily average computed from CGM events
Average glucose (mg/dL) Daily average computed from CGM events
Time in Range % of readings 70–180 mg/dL
Time below range % of readings below 70 mg/dL
Time above range % of readings above 180 mg/dL
Glucose SD / CV Standard deviation and coefficient of variation
GMI Glucose Management Indicator
Predicted glucose Control-IQ PLGS predicted value (mg/dL; shows when PLGS activates)

Insulin Delivery (14)

Sensor Description
Active insulin (IOB) Insulin on board
Basal rate Current basal rate (U/hr)
Last bolus Most recent bolus amount and timestamp
Last meal bolus Most recent meal bolus (units)
Total daily insulin TDI for today
Daily bolus / basal totals Split with basal percentage
Daily bolus count Number of boluses today
Daily carbs Total carbs entered today
Last carb entry Most recent carb entry with timestamp
Last bolus BG BG at time of bolus request (+ calculator details as attributes)
Last bolus carbs entered Carbs entered into bolus calculator
Last bolus correction Correction portion (units)
Last bolus food portion Food portion (units)
Estimated insulin remaining Fill volume minus cumulative deliveries (units)

Pump Battery (4)

Sensor Description
Battery percentage Current battery level (%)
Battery voltage Battery voltage (mV)
Battery remaining Remaining capacity (mAh)
Charging status Charging / Not charging

Alerts & Alarms (3)

Sensor Description
Last pump alert Most recent alert (human-readable name)
Last pump alarm Most recent alarm (human-readable name)
Active pump alerts Count of uncleared alerts + alarms

Pump Status (10)

Sensor Description
Control-IQ status Open Loop / Closed Loop
Activity mode Normal / Sleep / Exercise / Eating Soon
Pump suspended Suspended / Active
Pump suspend reason User / Alarm / Malfunction / Auto-PLGS
Cartridge insulin Remaining insulin (units)
Last cartridge fill amount Fill volume from API (units)
Last cartridge change Timestamp of last cartridge fill
Last site change Timestamp (derived from cartridge fill)
Last tubing change Timestamp of last tubing prime
CGM sensor type G6 / G7 / Libre 2 / None

Pump Settings (11)

Sensor Description
Active basal profile Profile name with full schedule as attributes
Control-IQ enabled On / Off
Control-IQ weight Configured weight (kg)
Control-IQ TDI Configured total daily insulin
Max bolus Maximum bolus limit (units)
Basal rate limit Maximum basal rate (U/hr)
CGM high/low alerts Alert thresholds (mg/dL)
BG high/low thresholds BG alert thresholds (mg/dL)
Low insulin alert Low reservoir threshold (units)

Device Info & Timestamps (7)

Sensor Description
Last glucose update When the last CGM reading was received
Last pump upload When the pump last uploaded to Tandem Source
Last update Integration data refresh timestamp
Pump serial number Device serial
Pump model Model name
Software version Firmware version
CGM usage Percentage of time CGM was active

Plus 6 long-term statistics (CGM, IOB, basal, carbs, total bolus, correction bolus) compatible with HA's Statistics Graph card. Import months of history with carelink.import_history.


Requirements

  • Tandem t:slim X2 with an active Tandem Source account
  • Tandem mobile app installed on Android or iOS and syncing regularly
  • Home Assistant 2023.1.0+ with HACS installed

Install

Via HACS (recommended)

  1. HACS → Integrations → ⋮ → Custom repositories → add https://github.com/jnctech/ha-tandem-pump (category: Integration)
  2. Find Tandem t:slim PumpDownload → restart Home Assistant
  3. Settings → Devices & Services → Add Integration → search Carelink → enter your Tandem Source email, password, and region

That's it. No developer account. Your pump's data starts flowing within minutes.

Or click the Add to HACS button at the top of this page.

Manual

Download the latest release. Delete the existing config/custom_components/carelink/ folder first (removes stale files from previous versions), then copy the new custom_components/carelink/ into place. Restart Home Assistant and add the integration as above.


How it works

Tandem t:slim X2  →  Tandem mobile app  →  Tandem Source cloud  →  Home Assistant (polls every 5 min)

The Tandem app uploads roughly once per hour when running unrestricted. New data appears in Home Assistant within minutes of each upload.

Keep the Tandem app running unrestricted on your phone. Battery optimisation on Android or Low Power Mode on iOS will delay or stop uploads. This is the most common cause of stale readings. Fix it now →


Backfill historical data

Import months of CGM, insulin, carb, and correction bolus history into the Statistics Graph:

Developer Tools → Actions → carelink.import_history → set a start and end date → Call Action

Field Required Description
start_date Yes First date to import (date picker or YYYY-MM-DD)
end_date No Last date to import — defaults to today

Data is fetched in 7-day chunks. The action is idempotent — safe to run multiple times.

Scenario Suggested range
App backgrounded for a day yesterday → today
App not syncing for a week 7 days ago → today
First install — full history earliest date → today (run in monthly chunks)

Example dashboard

A quick-start dashboard is included in examples/ to get you up and running. This is an early mock-up — future releases will include more templates and dashboarding guidance.

Requires (install via HACS → Frontend):

See examples/simple-dashboard.yaml and examples/template_sensors.yaml for details.

Upgrading

From v1.3.x

Entity IDs now include a tandem_ prefix.

Before After
sensor.last_glucose_level_mmol sensor.tandem_last_glucose_level_mmol

Update dashboards and automations after upgrading. Statistics Graph entities (sensor.carelink_*) are not affected.

From v1.2.x or earlier

You may see a phantom Tandem Pump device with 0 entities — safe to delete. See Duplicate Device →

If entities do not appear after upgrading, do a clean reinstall:

  1. Note your credentials (email, region, scan interval)
  2. Settings → Devices & Services → Carelink → Delete
  3. Update the integration and restart HA
  4. Re-add and enter your credentials

Troubleshooting

See TROUBLESHOOTING.md for the full guide.

Symptom Most likely cause Fix
Sensors show Unknown / data is stale Tandem app battery-optimised Mobile App Settings →
Authentication failure Wrong region, or MFA enabled Configuration Issues →
Sensors missing Wrong platform selected at setup Missing Sensors →

Open an issue: https://github.com/jnctech/ha-tandem-pump/issues


Development approach

This project is built with AI assistance (Claude) operating under strict engineering constraints:

  • All code passes SonarCloud quality analysis — reliability, security, maintainability, coverage, and duplication tracked per-PR
  • Ruff lint and format checks enforced in CI — no merge without passing
  • Bandit static security analysis runs on every push
  • pytest test suite with coverage reporting on every push
  • hassfest and HACS validation ensure Home Assistant compatibility
  • OpenSSF Scorecard supply chain security assessment
  • Structured AI code review on each PR: logic correctness, silent failure detection, and code simplification
  • Git Flow branching with conventional commits

AI is used as a tool. The engineering standards are not negotiable.

Have questions, ideas, or want to contribute? Open an issue or start a discussion — feedback from the community helps shape this project.


Credits

Built and maintained by @jnctech. Original Carelink integration by @yo-han. Tandem API research: jwoglom/tconnectsync by @jwoglom.


Medtronic CareLink users: This integration also supports Medtronic CareLink (limited sensors). Use your CareLink credentials when adding the integration.

About

Home Assistant integration for Tandem t:slim X2 insulin pumps. 69 sensors: glucose, insulin delivery, battery, alerts, bolus calculator, CGM statistics, basal profiles. Direct connection to Tandem Source API.

Topics

Resources

License

Contributing

Security policy

Stars

Watchers

Forks

Packages

 
 
 

Contributors

Languages

  • Python 99.9%