-
Notifications
You must be signed in to change notification settings - Fork 1
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
- Loading branch information
1 parent
ca525f4
commit f1481fa
Showing
3 changed files
with
82 additions
and
0 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,18 @@ | ||
name: Day-16 | ||
|
||
on: | ||
workflow_dispatch: | ||
push: | ||
paths: | ||
- '**16*' | ||
|
||
jobs: | ||
build: | ||
runs-on: ubuntu-latest | ||
|
||
steps: | ||
- uses: actions/checkout@v2 | ||
- name: Build | ||
run: cargo build --release --verbose | ||
- name: Run | ||
run: time target/release/aoc 16 |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,59 @@ | ||
Valve SY has flow rate=0; tunnels lead to valves GW, LW | ||
Valve TS has flow rate=0; tunnels lead to valves CC, OP | ||
Valve LU has flow rate=0; tunnels lead to valves PS, XJ | ||
Valve ND has flow rate=0; tunnels lead to valves EN, TL | ||
Valve PD has flow rate=0; tunnels lead to valves TL, LI | ||
Valve VF has flow rate=0; tunnels lead to valves LW, RX | ||
Valve LD has flow rate=0; tunnels lead to valves AD, LP | ||
Valve DG has flow rate=0; tunnels lead to valves DR, SS | ||
Valve IG has flow rate=8; tunnels lead to valves AN, YA, GA | ||
Valve LK has flow rate=0; tunnels lead to valves HQ, LW | ||
Valve TD has flow rate=14; tunnels lead to valves BG, CQ | ||
Valve CQ has flow rate=0; tunnels lead to valves TD, HD | ||
Valve AZ has flow rate=0; tunnels lead to valves AD, XW | ||
Valve ZU has flow rate=0; tunnels lead to valves TL, AN | ||
Valve HD has flow rate=0; tunnels lead to valves BP, CQ | ||
Valve FX has flow rate=0; tunnels lead to valves LW, XM | ||
Valve CU has flow rate=18; tunnels lead to valves BX, VA, RX, DF | ||
Valve SS has flow rate=17; tunnels lead to valves DG, ZD, ZG | ||
Valve BP has flow rate=19; tunnels lead to valves HD, ZD | ||
Valve DZ has flow rate=0; tunnels lead to valves XS, CC | ||
Valve PS has flow rate=0; tunnels lead to valves GH, LU | ||
Valve TA has flow rate=0; tunnels lead to valves LI, AA | ||
Valve BG has flow rate=0; tunnels lead to valves TD, ZG | ||
Valve WP has flow rate=0; tunnels lead to valves OB, AA | ||
Valve XS has flow rate=9; tunnels lead to valves EN, DZ | ||
Valve AA has flow rate=0; tunnels lead to valves WG, GA, VO, WP, TA | ||
Valve LW has flow rate=25; tunnels lead to valves LK, FX, SY, VF | ||
Valve AD has flow rate=23; tunnels lead to valves DF, GW, AZ, LD, FM | ||
Valve EN has flow rate=0; tunnels lead to valves ND, XS | ||
Valve ZG has flow rate=0; tunnels lead to valves SS, BG | ||
Valve LI has flow rate=11; tunnels lead to valves YA, XM, TA, PD | ||
Valve VO has flow rate=0; tunnels lead to valves AA, OD | ||
Valve AN has flow rate=0; tunnels lead to valves IG, ZU | ||
Valve GH has flow rate=15; tunnels lead to valves VA, PS | ||
Valve OP has flow rate=4; tunnels lead to valves AJ, TS, FM, BX, NM | ||
Valve BX has flow rate=0; tunnels lead to valves OP, CU | ||
Valve RX has flow rate=0; tunnels lead to valves CU, VF | ||
Valve FM has flow rate=0; tunnels lead to valves OP, AD | ||
Valve OB has flow rate=0; tunnels lead to valves WP, XW | ||
Valve CC has flow rate=3; tunnels lead to valves QS, LP, DZ, OD, TS | ||
Valve LP has flow rate=0; tunnels lead to valves LD, CC | ||
Valve NM has flow rate=0; tunnels lead to valves WH, OP | ||
Valve HQ has flow rate=0; tunnels lead to valves XW, LK | ||
Valve GW has flow rate=0; tunnels lead to valves SY, AD | ||
Valve QS has flow rate=0; tunnels lead to valves CC, XW | ||
Valve DF has flow rate=0; tunnels lead to valves AD, CU | ||
Valve XM has flow rate=0; tunnels lead to valves LI, FX | ||
Valve VA has flow rate=0; tunnels lead to valves CU, GH | ||
Valve GA has flow rate=0; tunnels lead to valves IG, AA | ||
Valve YA has flow rate=0; tunnels lead to valves LI, IG | ||
Valve XW has flow rate=20; tunnels lead to valves OB, HQ, QS, WH, AZ | ||
Valve XJ has flow rate=24; tunnel leads to valve LU | ||
Valve AJ has flow rate=0; tunnels lead to valves WG, OP | ||
Valve WH has flow rate=0; tunnels lead to valves XW, NM | ||
Valve TL has flow rate=13; tunnels lead to valves PD, DR, ZU, ND | ||
Valve OD has flow rate=0; tunnels lead to valves CC, VO | ||
Valve ZD has flow rate=0; tunnels lead to valves SS, BP | ||
Valve DR has flow rate=0; tunnels lead to valves DG, TL | ||
Valve WG has flow rate=0; tunnels lead to valves AJ, AA |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,5 @@ | ||
use crate::input_reader; | ||
|
||
pub fn run() { | ||
let input = input_reader::read_file_in_cwd("src/day_16.data"); | ||
} |