ICSSimSuite - ICS Simulation Suite

ICSSimSuite is an easy-to-use, open-source, and cross-platform simulation suite for Industrial Control Systems (ICS) with Modbus as the primary communication protocol. This suite allows users to simulate various ICS devices, such as HVAC systems, water pumps, batteries, and more, enabling testing and analysis of control systems in a safe and controlled environment.

Table of Contents

Installation

go install github.com/lopqto/icssimsuite@latest

Usage

icssimsuite config.toml

Configuration

Example configuration file can be found here: config.toml

Simulated Devices

HVAC System (Unit ID: 1)

Address Description Read/Write Type Function Code
1 Fan State R/W bool 0x01 (Coil)
100 Fan Speed R/W uint16 0x03 (Holding Register)
100 Temperature R float32 0x04 (Input Register)
102 Humidity R float32 0x04 (Input Register)
104 Room Temperature R float32 0x04 (Input Register)
106 Voltage R float32 0x04 (Input Register)
108 Current R float32 0x04 (Input Register)
110 Power R float32 0x04 (Input Register)
200 Uptime R uint32 0x04 (Input Register)

Pulse Counter (Unit ID: 2)

Address Description Read/Write Type Function Code
0 Pulse 1 State R/W bool 0x01 (Coil)
1 Pulse 2 State R/W bool 0x01 (Coil)
2 Pulse 3 State R/W bool 0x01 (Coil)
100 Pulse 1 Count R uint32 0x04 (Input Register)
102 Pulse 2 Count R uint32 0x04 (Input Register)
104 Pulse 3 Count R uint32 0x04 (Input Register)

Water Tank (Unit ID: 3)

Address Description Read/Write Type Function Code
0 Mode R/W bool 0x01 (Coil)
1 Valve State R/W bool 0x01 (Coil)
2 Pump State R/W bool 0x01 (Coil)
100 Water Level R uint16 0x04 (Input Register)
101 Max Tank Capacity R uint16 0x04 (Input Register)
102 Max Water Level R uint16 0x04 (Input Register)
103 Min Water Level R uint16 0x04 (Input Register)
104 Max Water Level Alarm R uint16 0x04 (Input Register)
105 Drain Rate R uint16 0x04 (Input Register)
106 Fill Rate R uint16 0x04 (Input Register)

Planned Devices

  • Water Tank
  • Battery
  • Solar Panel