Fix typo (#67)
Browse files Browse the repository at this point in the history
  • Loading branch information
Ines333 authored Oct 19, 2023
1 parent 15ef642 commit dcf5e35
Show file tree
Hide file tree
Showing 2 changed files with 31 additions and 31 deletions.
50 changes: 25 additions & 25 deletions Sources/ADT7410/ADT7410.swift
Original file line number Diff line number Diff line change
Expand Up @@ -38,11 +38,11 @@ public class ADT7410{
let operationMode = configuration.operationMode

if(operationMode == .ONE_SHOT || operationMode == .SHUTDOWN){
set0perationMode(.ONE_SHOT)
setOperationMode(.ONE_SHOT)
sleep(ms: 240)
}

return Self.toTemp(configuration.resulution,read(.TEMP_MSB,2))
return Self.toTemp(configuration.resolution,read(.TEMP_MSB,2))
}

/// Read the status.
Expand All @@ -51,21 +51,21 @@ public class ADT7410{
Status(read(.STATUS))
}

/// Read the temparture range.
/// Read the temperature range.
///
/// If the temperature falls below the min value or rises above the max value, the INT pin is triggered. Default temperature range is 10°C to 64°C.
/// - Returns: Temperture range of the INT Pin.
public func readIntTemperatureRange() -> (minTemp: Double,maxTemp: Double) {
( Self.toTemp(configuration.resulution, read(.SETPOINT_TEMP_LOW_MSB,2)),
Self.toTemp(configuration.resulution, read(.SETPOINT_TEMP_HIGH_MSB,2)))
( Self.toTemp(configuration.resolution, read(.SETPOINT_TEMP_LOW_MSB,2)),
Self.toTemp(configuration.resolution, read(.SETPOINT_TEMP_HIGH_MSB,2)))
}

/// Read the critical temparture.
/// Read the critical temperature.
///
/// If the temperature rises above the value, the CT pin is triggered. Default critical temparture is 147°C.
/// - Returns: Critical temparture for the CT pin.
/// If the temperature rises above the value, the CT pin is triggered. Default critical temperature is 147°C.
/// - Returns: Critical temperature for the CT pin.
public func readCTCriticalTemperature() -> Double{
Self.toTemp(configuration.resulution,read(.SETPOINT_TEMP_CRIT_MSB,2))
Self.toTemp(configuration.resolution,read(.SETPOINT_TEMP_CRIT_MSB,2))
}

/// Read the temperature hysteresis value for the THIGH, TLOW, and TCRIT temperature limits.
Expand Down Expand Up @@ -93,7 +93,7 @@ public class ADT7410{

/// Set the operation mode.
/// - Parameter mode: Operation mode
public func set0perationMode(_ mode: OperationMode){
public func setOperationMode(_ mode: OperationMode){
configuration.operationMode = mode
write([configuration.getByte()], to: .CONFIG)
}
Expand Down Expand Up @@ -126,31 +126,31 @@ public class ADT7410{
write([configuration.getByte()],to: .CONFIG)
}

/// Set the temparture range.
/// Set the temperature range.
///
/// If the temperature falls below the min value or rises above the max value, the INT pin is triggered. Default temperature range is 10°C to 64°C.
/// - Parameters:
/// - minTemp: Lower limit of the temperature range.
/// - maxTemp: Upper limit of the temperature range.
public func setIntTemperatureRange(min minTemp: Double, max maxTemp: Double ){
write(Self.toData(configuration.resulution, minTemp), to: .SETPOINT_TEMP_LOW_MSB)
write(Self.toData(configuration.resulution, maxTemp), to: .SETPOINT_TEMP_HIGH_MSB)
write(Self.toData(configuration.resolution, minTemp), to: .SETPOINT_TEMP_LOW_MSB)
write(Self.toData(configuration.resolution, maxTemp), to: .SETPOINT_TEMP_HIGH_MSB)
}

/// Set the critical temparture.
/// Set the critical temperature.
///
/// If the temperature rises above the value, the CT pin is triggered. Default critical temparture is 147°C.
/// - Parameter tempature: Critical temparture for the CT pin.
public func setCTCriticalTemperature(tempature: Double){
write(Self.toData(configuration.resulution,tempature), to: .SETPOINT_TEMP_CRIT_MSB)
/// If the temperature rises above the value, the CT pin is triggered. Default critical temperature is 147°C.
/// - Parameter temperature: Critical temperature for the CT pin.
public func setCTCriticalTemperature(temperature: Double){
write(Self.toData(configuration.resolution,temperature), to: .SETPOINT_TEMP_CRIT_MSB)
}

/// Set the temperature hysteresis value for the THIGH, TLOW, and TCRIT temperature limits.
///
/// The value is subtracted from the THIGH and TCRIT values and added to the TLOW value to implement hysteresis. allowed values are from 0°C-15°C and default temperature hyst is 5°C.
/// - Parameter tempature: Temperature hysteresis value.
public func setHyst(tempature: UInt8){
write([tempature], to: .SETPOINT_TEMP_HYST)
/// - Parameter temperature: Temperature hysteresis value.
public func setHyst(temperature: UInt8){
write([temperature], to: .SETPOINT_TEMP_HYST)
}

/// Set the configuration.
Expand Down Expand Up @@ -185,22 +185,22 @@ extension ADT7410 {
i2c.write([registerAddresse.rawValue]+data, to: serialBusAddress.rawValue)
}

static func toTemp(_ resulution: ADT7410.Resulution, _ data: [UInt8]) -> Double{
static func toTemp(_ resolution: ADT7410.Resolution, _ data: [UInt8]) -> Double{
let dataInt16 = (Int16(data[0]) << 8) | Int16(data[1])
let isPositiveTemp = dataInt16 >= 0

switch(resulution, isPositiveTemp){
switch(resolution, isPositiveTemp){
case (.r_13Bit,true): return Double(dataInt16 >> 3) / 16
case (.r_13Bit,false): return Double(dataInt16 >> 3 | 0b1 << 15) / 16
case (.r_16Bit,_ ): return Double(dataInt16) / 128
}
}

static func toData(_ resulution: ADT7410.Resulution, _ temp: Double) -> [UInt8]{
static func toData(_ resolution: ADT7410.Resolution, _ temp: Double) -> [UInt8]{
let isPositiveTemp = temp >= 0
var data:Int16 = 0

switch(resulution, isPositiveTemp){
switch(resolution, isPositiveTemp){
case (.r_13Bit,true): data = Int16(temp * 16) << 3
case (.r_13Bit,false): data = (Int16(temp * 16) << 3) | 0b1 << 15
case (.r_16Bit,_): data = Int16(temp * 128.0)
Expand Down
12 changes: 6 additions & 6 deletions Sources/ADT7410/Configuration.swift
Original file line number Diff line number Diff line change
Expand Up @@ -35,8 +35,8 @@ public extension ADT7410 {
public var temperatureDetectionMode: TemperatureDetectionMode = .COMPARATOR_MODE
/// The operation mode describes in which cycle the temperature is measured by the chip.
public var operationMode: OperationMode = .CONTINUOS
/// The sensor store the temperature in 13 bit or 16 bit resulution.
public var resulution: Resulution = .r_13Bit
/// The sensor store the temperature in 13 bit or 16 bit resolution.
public var resolution: Resolution = .r_13Bit

/// Initialize default configuration of a ADT7410.
public init(){}
Expand All @@ -51,7 +51,7 @@ public extension ADT7410 {
intOutputPolarity = .init(rawValue: configByte & 0b1000)!
temperatureDetectionMode = .init(rawValue: configByte & 0b10000)!
operationMode = .init(rawValue: configByte & 0b1100000)!
resulution = .init(rawValue: configByte & 0b10000000)!
resolution = .init(rawValue: configByte & 0b10000000)!
}

func getByte() -> UInt8{
Expand All @@ -60,7 +60,7 @@ public extension ADT7410 {
intOutputPolarity.rawValue |
temperatureDetectionMode.rawValue |
operationMode.rawValue |
resulution.rawValue )
resolution.rawValue )
}
}

Expand Down Expand Up @@ -110,8 +110,8 @@ public extension ADT7410 {
case SHUTDOWN = 0b1100000
}

/// The sensor store the temperature in 13 bit or 16 bit resulution.
enum Resulution: UInt8{
/// The sensor store the temperature in 13 bit or 16 bit resolution.
enum Resolution: UInt8{

/// Sign bit + 12 bits gives a temperature resolution of 0.0625°C.
case r_13Bit = 0b0
Expand Down