Skip to content

Conversation

@tykayn
Copy link
Contributor

@tykayn tykayn commented Aug 5, 2025

removes values that are more than the max known of 400kW to be set as the max power output of a charging station, adds a tag to correct values.
Also handles enumerations of this values to keep the maximum value.

The column evaluated in the dataset of French IRVE is "puissance_nominale" by the function "getPuissanceNominaleInKw".

Tested locally with docker on Monaco and Ile de France zones, returns proposals for the "charging_station:output" tag as "n kW" when finding good values.

@tykayn tykayn force-pushed the feat/irve-enrich-2 branch 2 times, most recently from 8a63ea2 to e60258e Compare August 5, 2025 14:05
@tykayn tykayn marked this pull request as ready for review August 11, 2025 20:59
@tykayn tykayn force-pushed the feat/irve-enrich-2 branch from 50ea73e to 0ffd8c2 Compare August 11, 2025 21:03
@frodrigo
Copy link
Contributor

Please, can you rework your PR in order to minimize code changes. Include only english comment to code.

@tykayn tykayn force-pushed the feat/irve-enrich-2 branch from fd2a6f1 to 6ee895c Compare September 2, 2025 09:04
@tykayn tykayn force-pushed the feat/irve-enrich-2 branch from 6ee895c to 103f219 Compare September 2, 2025 09:20
@tykayn
Copy link
Contributor Author

tykayn commented Sep 2, 2025

@frodrigo i updated the branch to minimize changes and translated comments in English

if raw is None:
return None

s = str(raw).strip()
Copy link
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

raw is not alredy a string ?

Copy link
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

now that you say it, it must be so. i changed it

if s == "":
return None

max_kw = getattr(self, "MAX_POWER_KW", 500)
Copy link
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

It s class attrib, will be defined.

Copy link
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

ok changed to a call of self

@frodrigo
Copy link
Contributor

frodrigo commented Nov 1, 2025

@tykayn please, can you review the comments.

@frodrigo frodrigo merged commit 55affd3 into osmose-qa:dev Nov 18, 2025
3 checks passed
@frodrigo
Copy link
Contributor

Thank you. Merged, but not deployed yet.

@Marc-marc-marc
Copy link
Contributor

I didn't understand how this could work, the pre-processed csv doesn't have puissance_nominalefield
maybe also take a look at Jungle-Bus/ref-EU-EVSE#15

@Marc-marc-marc
Copy link
Contributor

I also doubt that charging_station:output can be deduced from opendta in France :
opendata seems to give the nominal power per socket
charging_station:output gives the total power of the station.

Examples :

  • a station with 2 type2 22 kW : charging_station:output is somewhere between 22 and 44 kW
  • a station with 4 combo_ccs 400 kW : charging_station:output somewhere between 400 and 1600 kW.
  • a station Tesla V2 with 8 man_made=charge_point each with 2 socket:type2_combo:output=150 kW have a charging_station:output between 150 kW and 8x150 kW (and never 16x 150 kW due to power sharing between 2 sockets on the same dispenser (borne)
    puissance_nominale can only be used to set the "best" socket:*:output as @guiohm is trying todo with the PR listed above

@tykayn tykayn deleted the feat/irve-enrich-2 branch December 5, 2025 10:04
@tykayn
Copy link
Contributor Author

tykayn commented Dec 5, 2025

hi @Marc-marc-marc
it is true, the field seem to be missing in the pre-processed.csv, we should add it.

in the original open data it apprears to be associated to maybe one or more sockets, so it is per stall. But open data providers seem to disagree about wether a line in the spreadsheet is a stall or a pool of stalls.
in the wiki i noticed that charging_station:output is giving the max kW of a stall, but if it is not used to give this info we have a problem and maybe we need some cleanup or an other tag to clearly state that the number is a sum of the charge points, something like "charging_station:output:sum", because knowing the max kW of a stall is very useful, where knowing the sum of a pool is not useful at all for most consumers who want to know if their vehicle will charge at a reasonable speed at one stall.

it didnt make crash my dev env when i ran the analysis, so that is weird.

the PR of @guiohm is interesting, i hope it will bring some clarity.

@frodrigo
Copy link
Contributor

frodrigo commented Dec 5, 2025

it didnt make crash my dev env when i ran the analysis, so that is weird.

Note, there is download cache.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.