Skip to content

Releases: smarthausleben/ioBroker.wamo

v0.4.1 - CLRALA improvement

08 Aug 12:58
Compare
Choose a tag to compare

v0.4.0 - SafeFloor Connect release

26 Jul 08:43
Compare
Choose a tag to compare

Within the SafeFloor Connect release was, among other things, a new functionality for SafeFlore Connect devices implemented. Currently you can add up to 4 Devices. To read out this sensor with the current SafeFloor Sensor firmware (Version 2.21) please read the Disclaimer / Warning section below verry carefully.

For importent information about older versions please read the related capter in Importent release related information in the Wiki.

Disclaimer / Warning
The SafeFloor Connect data read out functionality is not yet really useful implemented into the device firmware. Currently the floor sensors are going immediately into sleep mode after they woke up and have send their information’s to the SYR cloud. Therefore there is no way to catch the device during this period yet. So in order to read out this sensors using this ioBroker adapter you have to activate the option “Keep online” in the adapter settings tab “SAFEFLOOR UNITS” and wake up the device by pushing the button inside the unit once. But this means that the device is not going into sleep mode anymore and therefore the device battery’s will be drained really quick. At the moment the only viable solution is the use of an battery adapter. This adapters you can easily get from amazon. Link to the adapter I use you can find in the specific hardware section for this project on my website.

v0.3.0 - Jam Protection

04 Apr 15:05
Compare
Choose a tag to compare

This Jam Protection release adds a scheduled move of the main valve which can be activated and scheduled in the adapter settings area (Tab: Tasks)

Be verry careful with this functionality because it will close and open the main valve in order to prevent it to get stuck in open position and therefore will not close in case of an leakage.

The Jam Protection can be planed using a CRON schedule which will also be configured in the adapter settings Tasks tab.
Be verry careful there as well, because if you schedule a jam protection for example every 1 Minute you are having big trouble because your main valve will close and open every minute!

During the Jam Protection activity, no regular states (Valve, Alarms etc.) will be updated in order to prevent false trigger you may have set on of those states.

If the main valve is already in closed position, the Jam Protection activity will not be performed in order to prevent opening the main valve.
If there is water consumption at start of Jam Protection the action will be delayed for 1 minute. After 10 faild attempts (water still flowing) Jam Protection will be aborted.

Disclaimer / Warning

If during the Jam Protection activity communication to the device gets lost or the WAMO adapter or ioBroker itself crashes or will be stopped, the main valve will stay in the last commanded position! This means if something gets wrong, the valve could be closed and needs to be opened by yourself using the related app or the button on the device itself.

v0.2.13

12 Oct 12:52
Compare
Choose a tag to compare
v0.2.13

v0.2.12

20 Sep 12:25
Compare
Choose a tag to compare
v0.2.12

v0.2.11

20 Sep 12:26
Compare
Choose a tag to compare
v0.2.11

v0.2.9

12 Aug 14:01
Compare
Choose a tag to compare
v0.2.9

v0.2.8

08 Aug 15:36
Compare
Choose a tag to compare
v0.2.8

v0.2.5

05 Aug 07:49
Compare
Choose a tag to compare

Readme version clean up

v0.2.4

05 Aug 07:19
Compare
Choose a tag to compare

Readme clean up