33 changes: 32 additions & 1 deletion docs/Smart-Meter-Interface.md
Original file line number Diff line number Diff line change
Expand Up @@ -148,7 +148,7 @@ Each meter typically provides multiple metrics (energy, voltage, power, current
| Parameter | Description |
| :--- | :--- |
| `<M>` | The meter number to which this decoder belongs |
| `<decoder>` | **Decoding specification**: OBIS as ASCII; SML, EBus, VBus, MODBus, RAW as HEX ASCII etc. _No space characters allowed in this section!_ <BR> **OBIS**: ASCII OBIS code terminated with `(` character which indicates the start of the meter value<BR>**Counter**: ASCII code 1-0:1.8.0\*255 for counter value, code 1-0:1.7.0\*255 for pulse rate (e.g. for actual power value)<BR> **SML**: SML binary OBIS as hex terminated with `0xFF` indicating start of SML encoded value<BR>**EBus, MODBus, RAW** - hex values of data blocks to compare:<BR> - `xx` = ignore value (1 byte) or `xN` = ignore N bytes<BR> - `ss` = extract a signed byte<BR> - `uu` = extract an unsigned byte<BR> - `UUuu` = extract an unsigned word (high order byte first)<BR> - `uuUU` = extract an unsigned word (low order byte first)<BR> - `UUuuUUuu` = extract an unsigned long word (high order byte first)<BR> - `uuUUuuUU` = extract an unsigned long word (low order byte first)<BR> - `SSss` = extract a signed word (high order byte first)<BR> - `ssSS` = extract a signed word (low order byte first)<BR> - `SSssSSss` = extract a signed long word (high order byte first)<BR> - `ssSSssSS` = extract a signed long word (low order byte first)<BR> - **on long word values**, if a trailing s is added at the end of the mask, word order is reversed<BR> - `bcdN` = extract a binary coded decimal N=2..12<BR> - `ffffffff` = extract a float value - IEEE754 decode<BR> - `FFffFFff` = extract a reverse float value - IEEE754 decode<BR>- `kstr` = decode KAMSTRUP data<BR>- `pm(x.y.z)` = pattern match(asci obis code)<BR>- `pm(hHHHHHH)` = pattern match(hex obis code)<BR>- `pm(rHHHHHH)` = pattern match(any hex pattern)<BR><BR>if using **VBus** - hex values of data blocks to compare:<BR> - `AAffffaddrff0001ffff` = VBus-specific hex header: `AA`-sync byte, `addr`-the reversed address of the device. To find his out first look up the known [hex address of the device](http://danielwippermann.github.io/resol-vbus/vbus-packets.html). E.g. Resol DeltaSol BS Plus is `0x4221`. Reverse it (without `0x`) and you will get `21 42` hex characters. Now turn on raw dump mode using command `sensor53 d1` and look for rows starting with `aa`, containing your reversed address at position 4 and 5 and `00 01` hex characters at position 7 and 8. If found, the entire header will be 10 hex characters long including `aa` (20 ascii chars without space, e.g. for Resol DeltaSol BS Plus this will be `AA100021421000010774`). At position 9 you see the number of frames containing readable data. To turn off raw dump use `sensor53 d0`.<BR> - `v` = VBus protocol indicator<BR> - `oN` = extract data from offset `N` (see offsets of your device in [VBus protocol documentation](http://danielwippermann.github.io/resol-vbus/vbus-packets.html))<BR> - `u` or `s` = extract unsigned or signed data<BR> - `w` or `b` = extract word or byte<BR>**End of decoding**: `@` indicates termination of the decoding procedure.<BR>- `(` following the `@` character in case of obis decoder indicates to fetch the 2. value in brackets, not the 1. value. (e.g. to get the second value from an obis like `0-1:24.2.3(210117125004W)(01524.450*m3)`)<BR>- decoding multiple values coming in brackets after each other is possible with `(@(0:1`, `(@(1:1`, `(@(2:1` and so on (e.g. to get values from an obis like `0-0:98.1.0(210201000000W)(000000.000*kWh)(000000.000*kWh)`)<BR>- decoding a 0/1 bit is indicated by a `@` character followed by `bx:` (x = `0..7`) extracting the corresponding bit from a byte. (e.g.: `1,xxxx5017xxuu@b0:1,Solarpump,,Solarpump,0`)<BR>- in case of MODBus/Kamstrup, `ix:` designates the index (x = `0..n`) referring to the requested block in the transmit section of the meter definition
| `<decoder>` | **Decoding specification**: OBIS as ASCII; SML, EBus, VBus, MODBus, RAW as HEX ASCII etc. _No space characters allowed in this section!_ <BR> **OBIS**: ASCII OBIS code terminated with `(` character which indicates the start of the meter value<BR>**Counter**: ASCII code 1-0:1.8.0\*255 for counter value, code 1-0:1.7.0\*255 for pulse rate (e.g. for actual power value)<BR> **SML**: SML binary OBIS as hex terminated with `0xFF` indicating start of SML encoded value<BR>**EBus, MODBus, RAW** - hex values of data blocks to compare:<BR> - `xx` = ignore value (1 byte) or `xN` = ignore N bytes<BR> - `ss` = extract a signed byte<BR> - `uu` = extract an unsigned byte<BR> - `UUuu` = extract an unsigned word (high order byte first)<BR> - `uuUU` = extract an unsigned word (low order byte first)<BR> - `UUuuUUuu` or `U32` = extract an unsigned long word (high order byte first)<BR> - `uuUUuuUU` or `u32` = extract an unsigned long word (low order byte first)<BR> - `SSss` = extract a signed word (high order byte first)<BR> - `ssSS` = extract a signed word (low order byte first)<BR> - `SSssSSss` or `S32` = extract a signed long word (high order byte first)<BR> - `ssSSssSS` or `s32` = extract a signed long word (low order byte first)<BR> - **on long word values**, if a trailing s is added at the end of the mask, word order is reversed<BR>- `U64` = extract an unsigned 64 long word<BR>- `u64` = extract an unsigned 64 long word (low order byte first)<BR> - `bcdN` = extract a binary coded decimal N=2..12<BR> - `ffffffff` = extract a float value - IEEE754 decode<BR> - `FFffFFff` = extract a reverse float value - IEEE754 decode<BR>- `kstr` = decode KAMSTRUP data<BR>- `pm(x.y.z)` = pattern match(asci obis code)<BR>- `pm(hHHHHHH)` = pattern match(hex obis code)<BR>- `pm(rHHHHHH)` = pattern match(any hex pattern)<BR><BR>if using **VBus** - hex values of data blocks to compare:<BR> - `AAffffaddrff0001ffff` = VBus-specific hex header: `AA`-sync byte, `addr`-the reversed address of the device. To find his out first look up the known [hex address of the device](http://danielwippermann.github.io/resol-vbus/vbus-packets.html). E.g. Resol DeltaSol BS Plus is `0x4221`. Reverse it (without `0x`) and you will get `21 42` hex characters. Now turn on raw dump mode using command `sensor53 d1` and look for rows starting with `aa`, containing your reversed address at position 4 and 5 and `00 01` hex characters at position 7 and 8. If found, the entire header will be 10 hex characters long including `aa` (20 ascii chars without space, e.g. for Resol DeltaSol BS Plus this will be `AA100021421000010774`). At position 9 you see the number of frames containing readable data. To turn off raw dump use `sensor53 d0`.<BR> - `v` = VBus protocol indicator<BR> - `oN` = extract data from offset `N` (see offsets of your device in [VBus protocol documentation](http://danielwippermann.github.io/resol-vbus/vbus-packets.html))<BR> - `u` or `s` = extract unsigned or signed data<BR> - `w` or `b` = extract word or byte<BR>**End of decoding**: `@` indicates termination of the decoding procedure.<BR>- `(` following the `@` character in case of obis decoder indicates to fetch the 2. value in brackets, not the 1. value. (e.g. to get the second value from an obis like `0-1:24.2.3(210117125004W)(01524.450*m3)`)<BR>- decoding multiple values coming in brackets after each other is possible with `(@(0:1`, `(@(1:1`, `(@(2:1` and so on (e.g. to get values from an obis like `0-0:98.1.0(210201000000W)(000000.000*kWh)(000000.000*kWh)`)<BR>- decoding a 0/1 bit is indicated by a `@` character followed by `bx:` (x = `0..7`) extracting the corresponding bit from a byte. (e.g.: `1,xxxx5017xxuu@b0:1,Solarpump,,Solarpump,0`)<BR>- in case of MODBus/Kamstrup, `ix:` designates the index (x = `0..n`) referring to the requested block in the transmit section of the meter definition
| `<scale>` | scaling factor (divisor) or string definition<BR>This can be a fraction (e.g., `0.1` = result * 10), or a negative value. When decoding a string result (e.g. meter serial number), use `#` character for this parameter _(Note: only one string can be decoded per meter!)_. For OBIS, you need a `)` termination character after the `#` character. |
| `<offs>` | optional offset must precede with + or - sign, note: offset is applied before scale!|
| `<label>` | web UI label (max. 23 characters) |
Expand Down Expand Up @@ -3012,3 +3012,34 @@ Tested on an AEConversion INV500-90 with RS485 interface.
1,212717x4UUuux4@1000,Energie,kWh,energy_sun,3
#
```
### SMA Solar Inverter (TCP MODBus)

??? summary "View script"

```
>D
>B
=>sensor53 r
>M1
+1,[192.168.56.91],m,0,502,SMA,0,10,03047741,03047747,03047777,03047831,03047833,03047835,030478ED,030478EF,030478F1,03047893,030478E9,0304787D,03047881,r03047AA50004,r03047AA90004
1,030404U32@i0:1000,Gesamtertrag,kWh,v1,3
1,030404U32@i1:1000,Tagesertrag,kWh,v2,3
1,030404U32@i2:1000,Einspeisung_ges,kWh,v3,3
1,030404S32@i3:100,DC Str. A,A,v4,2
1,030404S32@i4:100,DC Sp. A,V,v5,2
1,030404S32@i5:100,DC Le. A,W,v6,2
1,030404S32@i6:100,DC Str. B,A,v7,2
1,030404S32@i7:100,DC Sp. B,V,v8,2
1,030404S32@i8:100,DC Le. B,W,v9,2
;
1,030404S32@i9:100,AC Le.,W,v10,2
;
1,030404S32@i10:10,WR_Temp,°C,v11,2
;
1,030404U32@i11:1,Batterieladung,%%,v12,0
1,030404S32@i12:10,Batt_Temp,°C,v13,2
;
1,030408U64@i13:1000,Batt_Ladung,kWh,v14,3
1,030408U64@i14:1000,Batt_EntLadung,kWh,v15,3
#
```

0 comments on commit 9e8a32f