Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Update Smart-Meter-Interface.md #1381

Open
wants to merge 1 commit into
base: master
Choose a base branch
from
Open
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
49 changes: 48 additions & 1 deletion docs/Smart-Meter-Interface.md
Original file line number Diff line number Diff line change
Expand Up @@ -1169,7 +1169,54 @@ For SGM-C4, double-tariff variants or meters measuring supply remove the appropr

Overview of the codes
![image](https://user-images.githubusercontent.com/5443580/186160623-3db77d01-429f-49db-86ff-d804578aad99.png)


### EFR SGM-D4A920N
By default, the energy meter only sends the total energy values. To be able to read all the other values, you need to enter the PIN and set `InF on`. (can be done with "optical" button)
The PIN must be requested from the metering provider, which is usually your local grid provider and not your energy provider (but they know whom to ask). After entering the PIN and setting `InF on`, all the values will be available.
A few values I wasn't able to figure out, but the most relevant are there. If you want to try this parameters you have to comment out the lines (remove leading ;)

??? summary "View script"
```
>D
>B
spinm(4 1)
=>sensor53 r
>M 1
+1,3,s,0,9600,sml
1,77070100010800FF@1000,Bezug (180),kWh,zaehlerstand_180,3
;1,77070100010801FF@1,Tarif 1 (180),Wh,zaehlerstand_tarif_1_180,3
;1,77070100010802FF@1,Tarif 2 (180),Wh,zaehlerstand_tarif_2_180,3
1,77070100020800FF@1000,Einspeisung (280),kWh,zaehlerstand_280,3
;1,77070100020801FF@1,Tarif 1 (280),Wh,zaehlerstand_tarif_1_280,3
;1,77070100020802FF@1,Tarif 2 (280),Wh,zaehlerstand_tarif_2_280,3
1,770701000E0700FF@1,Netz Frequenz,Hz,netz_frequenz,1
1,77070100100700FF@1,aktuelle Wirkleistung,W,aktuelle_wirkleistung,0
1,770701001F0700FF@1,Strom L1,A,strom_l1,2
1,77070100200700FF@1,Spannung L1,V,spannung_l1,1
1,77070100240700FF@1,Wirkleistung L1,W,wirkleistung_l1,0
1,77070100330700FF@1,Strom L2,A,strom_l2,2
1,77070100340700FF@1,Spannung L2,V,spannung_l2,1
1,77070100380700FF@1,Wirkleistung L2,W,wirkleistung_l2,0
1,77070100470700FF@1,Strom L3,A,strom_l3,2
1,77070100480700FF@1,Spannung L3,V,spannung_l3,1
1,770701004C0700FF@1,Wirkleistung L3,W,wirkleistung_l3,0
1,77070100510701FF@1,Phasenwinkel U L1/L2,°,phasenwinkel_u_l1_l2,0
1,77070100510702FF@1,Phasenwinkel U L1/L3,°,phasenwinkel_u_l1_l3,0
1,77070100510704FF@1,Phasenwinkel I/U L1,°,phasenwinkel_i_u_l1,0
1,7707010051070FFF@1,Phasenwinkel I/U L2,°,phasenwinkel_i_u_l2,0
1,7707010051071AFF@1,Phasenwinkel I/U L3,°,phasenwinkel_i_u_l3,0
;1,77070100600100FF@#,Seriennummer,,seriennummer,0
;1,7707010060320101@#,Hersteller,,hersteller,0
;1,7707010060320104@#,HW Version,,hw_version,0
;1,7707010060320204@#,HW Version PCB2,,hw_version,0
;1,7707010060320404@#,Parameter Version,,parameter_version,0
;1,77070100605A0201@#,FW Checksum,,fw_checksum,0
;1,77070100605A0202@#,Unbekannt 2,,unbekanntes_mqtt_topic_2,0
;1,7707010000020000@#,Firmware Version,,firmwareversion,0
;1,7707010000020001@#,Unbekannt 1,,unbekanntes_mqtt_topic_1,0

```

### Elster / Honeywell AS1440 (OBIS)

Based on Landis script with changed timings in the >F section, as AS1440 seems to be slower in responding.