The Convert Voltage to CSD panel transforms voltage values into current source density (CSD) values for either an EEGset or an ERPset.
This operation makes use of Kayser & Tenke’s CSD Toolbox, which computes a surface Laplacian function to the data at each time point after applying a spherical spline interpolation. We recommend using the default parameters in most situations. You simply click Run, and it will create a new EEGset or ERPset with CSD values instead of voltage values.