c3-lua

A native Lua library for communicating with the ZKAccess C3 Access Control Panels.

This library intends to implement the same functionality as provided by the ZKAccess C3 PullSDK API.

Usage

local C3 = require("c3.c3")

C3.connect("1.1.1.1")
print("SessionId: " .. C3.SessionId())
C3.disconnect()

Protocol

The C3 access panels communicate using RS485 or TCP/IP. The connection is optionally secured by a password. The wire protocol for the access panels is binary, with the following datagram both for requests (from client to equipment) and responses:

Byte 0 1 2 3 4 5,6,7,8, ... n-2, n-1 n
Meaning Start Version Command Length Lsb Length Msb Data Checksum End
Value 0xAA 0x01 0x55

The start bytes 0, 1 and last byte have a fixed value. The Command is one of the following (only listing commands supported by this library)

Code Command
0x76 Connect (session initiation)
0x02 Disconnection (session end)
0x05 Device control command
0x0B Retrieve realtime log
0xC8 Response (confirm successful execution of command)

The Length field (2 bytes, in Little Endian encoding) contains the number of bytes of the Data field. The Data field (as of byte 5) typically has at least 4 bytes:

  • Session Id (2 bytes, in Little Endian encoding): The session identifier assigned by the equipment in response to a session initiation command
  • Message Number (2 bytes, in Little Endian encoding): A message sequence number that starts from 0 (the session initiation command) and is increased with every command send
Byte 5 6 7 8 ...
Meaning SessionId Lsb SessionId Msb Message Nr Lsb Message Nr Msb Payload

The Checksum is a CRC-16 checksum calculated over the full message excluding the Start and End byte.

API

connect

connect(host, port)

The method is used to connect a C3 device using TCP. RS485 is not supported. Neither is using a password to secure the connection. This method must be called before any other method and initializes a C3 session. Returns true in case of a successful connection.

disconnect

disconnect()

Disconnects from the C3 access panel and ends the session.

getRTLog

getRTLog()

This method acquires the realtime event log generated by the access panel. It contains the door and/or alarm status of the equipment. It returns an array of RTDAStatusRecord and/or RTEventRecord objects.

getDeviceParameters

getDeviceParameters(params_arr)

This method reads device parameters, both configuration and static parameters. The argument is a list of (maximum 30) strings with the parameter names for which the values need to be returned. Valid values are (reduced list): ~SerialNumber, AntiPassback, AuxInCount, AuxOutCount, BackupTime, ComPwd, DateTime, DaylightSavingTime, DaylightSavingTimeOn, DLSTMode, Door{N}CancelKeepOpenDay, Door{N}CloseAndLock, Door{N}Detectortime, Door{N}Drivertime, Door{N}FirstCardOpenDoor, Door{N}ForcePassWord, Door{N}Intertime, Door{N}KeepOpenTimeZone, Door{N}MultiCardOpenDoor, Door{N}SensorType, Door{N}SupperPassWord, Door{N}ValidTZ, Door{N}VerifyType, GATEIPAddress, InBIOTowWay , InterLock, IPAddress, LockCount, NetMask, ReaderCount, Reboot, RS232BaudRate, StandardTime, WatchDog, WeekOfMonth{N}, For the full list and the meaning of the returned value, refer to the PullSDK specification. The return value is a table of key/value pairs with the parameter name and value.

controlDevice

controlDevice(control_command_object)

Sends a control command to the access panel to perform an action on the requipment. The control_command is an instance of one of the following objects:

  • C3.ControlDeviceOutput(door_number, address, duration): Open or close a door or auxilary device
    • door_number: The number of the door or auxilary to control (1-4)
    • address: Determines whether door_number is a door (address = 1) or an auxilary (address = 2)
    • duration: The duration for which the door will be open; 0 will close the door immediately, 1-254 will leave the door open for that number of seconds: 255 will leave the door open for an undetermined period
  • C3.ControlDeviceCancelAlarm(): Cancel any triggered alarm
  • C3.ControlDeviceRestartDevice(): Reboot the access panel
  • C3.ControlDeviceNOState(door_number, enable_disable): Change the normal open/close state for the door controller
    • door_number: The number of the door to control (1-4)
    • enable_disable: Enable normally open mode (enable_disable = 1) or disable normally open mode for the door (enable_disable = 0, default)

setDebug

set_debug(debug_on_off)

Sets or unsets debug mode. In debug mode, the library prints a lot of detailed internal information, specifically regarding protocol binary data.