Skip to content

Master Equation Calculations

Judit Zádor edited this page Jun 16, 2024 · 3 revisions

Back to Input

parameter default description use with...
me_code mess Name of the master equation code, mess for MESS and mesmer for MESMER.
mess_command mess Command to run MESS. MESS
TemperatureList 1000 See MESS manual. MESS
PressureList 760 See MESS manual. MESS
EnergyStepOverTemperature .2 See MESS manual MESS
ExcessEnergyOverTemperature 30 See MESS manual. MESS
ModelEnergyLimit 400 See MESS manual. MESS
CalculationMethod direct See MESS manual. MESS
ChemicalEigenvalueMax 0.2 See MESS manual. MESS
EnergyRelaxationFactor 200 See MESS manual. MESS
EnergyRelaxationPower 0.85 See MESS manual. MESS
EnergyRelaxationExponentCutoff 15 See MESS manual. MESS
epsilon 0. The epsilon parameter from the Lennard-Jones potential in units of epsilon_unit. MESS
epsilon_unit K Unit of the epsilon in the Lennard-Jones potential. Can be K, cm-1, or J/mol. MESS
sigma 0. The sigma parameter from the Lennard-Jones potential in Angstrom. MESS
collider He The symbol for the collider, He, N2, Ar, O2 or H2O. MESS
mesmer_command mesmer Command to run MESMER MESMER

While KinBot is fully restartable, some parameters cannot be changed upon restart without compromising the calculations. These are marked with an asterisk (*).