Notifications
You must be signed in to change notification settings - Fork 11
SW_ConfigParams
Rolf Obrecht edited this page Aug 21, 2024
·
29 revisions
This is a (mostly) complete list of configuration parameters for telex.json, grouped by modules. Entries without module spec are global.
Module | Parameter | Default | Type or range | Comment |
---|---|---|---|---|
(Global) | devices | {} | dict | Dictionary of device-node-IDs (modules) |
(Global) | errorlog_path | error_log | string | Directory path for error log |
(Global) | errorlog_level | "INFO" | "NOTSET", "DEBUG", "INFO", "WARN", "ERROR", "CRITICAL" |
verbosity of error log (see python manual) |
(Global) | wru_id | [none] | string | Software-WRU-ID |
(Global) | wru_replace_always | false | false / true | if true, always replace Hardware-WRU by Software-WRU |
(Global) | continue_with_no_printer | true | false / true | if true, ignore missing / faulty printer device; if false, abort connections if teleprinter fails to start up |
(Global) | power_off_delay | 20 | non-neg. int | time in seconds from end-of-conection until switching off TTY power |
(Global) | power_button_timeout | 300 | non-neg. int | time in seconds from switching on TTY power by means of button PT until switch off PWR |
(Global) | dial_timeout | 2.0 | '+‘ / float (0.0...55.0) | idle time after last dialled digit to start dial process; if ‚+‘, „plus-dialling“ selected, if ‚0‘, instant dialling is used (see Configuration File ) |
(Global) | welcome_msg | true | false/true | if true, print the welcome msg (DateTime stamp) at connection start |
Archive | path | "archive" | string | path to archive directory |
CH340TTY | mode | "TW39" | "TW39", "TWM", "V10", "EDS" | "TW39": Number Switch Dial "TWM" : keypad Dial, "V10" : FS200/Fs220 mode "EDS" : |
CH340TTY | portname | "/dev/ttyUSB0" | string | serial port used |
CH340TTY | baudrate | 50 | 50, 75, 100 | Baud rate |
CH340TTY | bytesize | 5 | 5 … 8 | # of Databits |
CH340TTY | stopbits | 1.5 | 1, 1.5, 2 | # of stopbits |
CH340TTY | coding | 0 | 0,1,2,3 | 0:ITA2=CCITT2, 1:US, 2:MKT2, 3:ZUSE (see txCode.md) |
CH340TTY | loopback | true | false / true | if true, sent characters are removed from receive buffer |
CH340TTY | loc_echo | false | false / true | if true, echo back all characters received from teleprinter |
CH340TTY | inverse_dtr | false | false / true | If true, use inverted signal |
CH340TTY | inverse_rts | false | false / true | If true, use inverted signal |
ED1000SC | recv_squelch | 100 | positive integer | Defines the power threshold below which the filter output for A/Z level is ignored; if needed, can be determined experimentally using helper script ED1000/squelch_check.py (see docstring inside). |
ED1000SC | recv_debug | false | false / true | If true, output recv_debug.log file inside which the repective filter power output levels for every sample are recorded. Use only for debugging (file will grow quickly). |
ED1000SC | send_WB_pulse | false | false / true | If true, send pulse to signal ready-to-dial condition like with the current interface. |
ED1000SC | unres_threshold | 100 | positive integer | Duration in ms that piTelex waits for the teleprinter, after it started sending Z level, until the teleprinter returns the Z level to signal readiness state. Raise if the teleprinter needs more time to start up for special setups, e.g. when switching mains using ESC-TP0/TP1 commands. |
ED1000SC | recv_f0 | 2250 | number | RX frequency 0 in Hz (A level) |
ED1000SC | recv_f1 | 3150 | number | RX frequency 1 in Hz (Z level) |
ED1000SC | devindex | null | null or positive integer (0 included) | pyaudio‘s device index for the intended audio device; use ED1000/audiotest.py to list currently available devices (0=auto, 1=1st device, 2=2nd ...). |
ED1000SC | baudrate | 50 | 50, 75, 100 | Baud rate |
ED1000SC | send_f0 | 500 | number | TX frequency 0 in Hz (A level) |
ED1000SC | send_f1 | 700 | number | TX frequency 1 in Hz (Z level) |
ED1000SC | zcarrier | false | false / true | If true, piTelex will send continous A level in idle state. Most teleprinters don‘t need this. |
IRC | directed_only | false | false / true | ? |
IRC | irc_server | "irc.nerd2nerd.org" | string | Name or IPV4 address of IRC server |
IRC | irc_port | 6697 | 1024 ... 65535 | IP port of IRC server |
IRC | irc_nick | "telextest" | string | Nick name |
IRC | irc_channel | "#tctesting" | string | IRC Channel to use |
ITelex | tns_srv | defaults | list of FQDNs,IPV4-addresses | specify tns-hosts to use, should normally be left at the built in values, use for debugging purposes only |
ITelexClient | tns_port | 11811 | number | TCP port number of tns_host (tns=“TeilNehmerServer“) |
ITelexClient | userlist | "userlist.csv" | string | filename of file containing speed dials, syntax see userlist_example.csv |
ITelexSrv | port | 2342 | 1024 ... 65535 | TCP port number (ports <1024 are privileged and not accessible for normal users) |
ITelexSrv | tns_dynip_number | 0 | positive integer | Initially 0 (disable dynamic IP update). Set to own i-Telex calling number to enable dynamic IP update – must be agreed on with i-Telex administrators. |
ITelexSrv | number | 0 | positive integer | alias for tns-dynip-number, deprecated |
ITelexSrv | tns_pin | None | positive integer < 65536 | PIN for dynamic IP update; set according to i-Telex administrator‘s instructions |
ITelexSrv | block_ascii | true | false/true | if true, block non-I-Telex connections (ASCII, PortScans,...) (from Rel 2023-07 on) |
Log | filename | "log.txt" | string | path to logfile |
News | newspath | "./news" | string | path to news file |
News | print_path | false | false / true | If true, reformat newspath suitable for printing; no functionality by now due to internal affairs… |
RPiCtrl | pin_number_switch | 0 | number | GPIO# of pin connected to number switch of CCU; if 0, use kbd dialling; use a pullup resistor 10kOhm to 3.3V |
RPiCtrl | inv_number_switch | true | false / true | If true, use inverted signal on pin |
RPiCtrl | pin_button_AT | 0 | number | GPIO# of button AT (optional) Button connects to GND |
RPiCtrl | pin_button_ST | 0 | number | GPIO# of button ST (optional) Button connects to GND |
RPiCtrl | pin_button_LT | 0 | number | GPIO# of button LT (optional) Button connects to GND |
RPiCtrl | pin_button_1T | 0 | number | GPIO# of Single button (optional), press button 1T repeatedly to cycle through states Offline, Active, WB |
RPiCtrl | pin_button_PT | 0 | number | GPIO# of power button PT (optional) Button connects to GND |
RPiCtrl | delay_AT | 0 | non-neg. int | delay in seconds before reacting on button AT pressed |
RPiCtrl | delay_ST | 0 | non-neg. int | delay in seconds before reacting on button ST pressed |
RPiCtrl | pin_LED_A | 0 | number | GPIO# of LED indicating status „A“ ; LED connects to GND (1kOhm in series!) |
RPiCtrl | pin_LED_WB | 0 | number | GPIO# of LED indicating status „WB“ ; LED connects to GND |
RPiCtrl | pin_LED_WB_A | 0 | number | GPIO# of LED indicating status „WB" or status „A“ ; LED connects to GND (1kOhm in series!) |
RPiCtrl | pin_LED_LT | 0 | number | GPIO# of LED indicating Local Mode ; LED connects to GND (1kOhm in series!) |
RPiCtrl | pin_LED_status_R | 0 | number | GPIO# of RED status LED ; LED connects to GND (1kOhm in series!) |
RPiCtrl | pin_LED_status_G | 0 | number | GPIO# of GREEN status LED ; LED connects to GND (1kOhm in series!) |
RPiCtrl | pin_LED_Z | 0 | number | GPIO# of LED indicating status "Z" and "ZZ"; LED connects to GND (1kOhm in series!) |
RPiCtrl | LED_Z_heartbeat | 6 | number | defines heartbeat duty cycle for LED_Z , off if set to 0 (=> LED_Z always on), otherwise LED_Z is turned off for (LED_Z_heartbeat * 500ms) and on for 500ms |
RPiCtrl | pin_power | 0 | number | GPIO# of pin for power (save) relay / SSR |
RPiCtrl | inv_power | false | false / true | If true, use inverted signal on pin |
RPiCtrl | pin_button_U1 | 0 | number | GPIO# of button user1 (optional) Button connects to GND |
RPiCtrl | text_button_U1 | "RY" | string | text to print if button user1 is pressed |
RPiCtrl | pin_button_U2 | 0 | number | GPIO# of button user2 (optional) Button connects to GND |
RPiCtrl | text_button_U2 | "RYRY ... RY" | string | Text associated with button user2 |
RPiCtrl | pin_button_U3 | 0 | number | GPIO# of button user3 (optional) Button connects to GND |
RPiCtrl | text_button_U3 | "#" | string | Text associated with button user3 |
RPiCtrl | pin_button_U4 | 0 | number | GPIO# of button user4 (optional) Button connects to GND |
RPiCtrl | text_button_U4 | "@" | string | Text associated with button user4 |
RPiTTY | mode | "TW39" | string | "TW39" for TTY‘s with current loop and number switch, "TW39H" if using H-bridge hardware, "TWM" for keyboard dialling, "V10" for machines with V.10 interface (mainly TeKaDe FS200 / FS220), "AGT" , "AGT-TWM", "AGT-TW39" for use with austrian AGT and SEU-M |
RPiTTY | baudrate | 50 | 38 ... 50 … 200 | Baud rate |
RPiTTY | bytesize | 5 | 5 … 8 | # of databits |
RPiTTY | stopbits | 1.5 | 1 / 1.5 / 2 | # of stopbits |
RPiTTY | pin_txd | 17 | number | GPIO# of TX-Data pin |
RPiTTY | inv_txd | false | false / true | If true, use inverted signal on TX-Data pin, not possible with PIGPIO |
RPiTTY | pin_dir | 0 | number | GPIO# of DIR pin. This pin is set to 1 on transmitting each byte for hardware loopback supression |
RPiTTY | pin_rxd | 27 | number | GPIO# of RX-Data pin |
RPiTTY | inv_rxd | false | false / true | If true, use inverted signal on RX-Data pin |
RPiTTY | pin_relay | 22 | number | GPIO# of relay coil pin; in non-FSG mode used to switch the line power of the teletype; in FSG mode, relay is used to invert the polarity of the current loop when a connection is established; see corresponding hardware description |
RPiTTY | inv_relay | false | false / true | If true, use inverted signal on pin |
RPiTTY | pin_power | 0 | number | GPIO# of pin used to switch power relay/SSR |
RPiTTY | inv_power | false | false / true | If true, use inverted signal on pin |
RPiTTY | pin_number_switch | 6 | number | GPIO# of pin connected to the number switch; often wired to pin_rxd. Set to -1 to enable pin_number_switch in module RPiCtrl Set to 0 to select keyboard dialling |
RPiTTY | inv_number_switch | false | false / true | If true, use inverted signal on pin |
RPiTTY | use_observe_line | true | false / true | If true, monitor pin_observe_line for state changes of >0,5s |
RPiTTY | pin_observe_line | [pin_rxd] | number | GPIO# of pin to observe |
RPiTTY | inv_observe_line | [inv_rxd] | false / true | If true, use inverted signal on pin |
RPiTTY | nZZ_observe_line | false | false / true | (For TeKaDE FS2X0): Observe LIN button in deep sleep mode, should be true if power relay is used |
RPiTTY | coding | 0 | 0,1,2,3 | 0:ITA2=CCITT2, 1:US, 2:MKT2, 3:ZUSE (see txCode.md) |
RPiTTY | loopback | true | false / true | if true, sent characters are removed from receive buffer |
RPiTTY | timing_rxd | false | false / true | ? |
RPiTTY | WB_pulse_length | 40 | number | set length of WB pulse in milliseconds |
RPiTTY | double_WR | false | false / true | if true, add an extra <CR> to give the old machines more time to move to the start of the line |
RPiTTY | txd_powersave | false | false/true | If true, switch off the loop current in "ZZ" status. Should be used together with pin_power option of device RPiCtrl (from Rel 2024-08 on) |
Screen | show_BuZi | true | false / true | If true, show special characters for Bu / Zi on Screen |
Screen | show_capital | false | false / true | if true, use capital letters on screen |
Screen | show_ctrl | true | false / true | if true, show control sequences on screen |
Screen | show_info | false | false / true | if true, show additional info on screen |
Screen | show_line | true | false / true | if true, show vertical border line „|“ on screen |
ShellCmd | LUT | {} | dict | Look-up table of user defined commands to be executed in response to piTelex ESC commands; form: {„key1“: „cmd1“, „key2“: „cmd2“,..,..}. „cmd1“ will be executed after typing key1 a.s.o.. example: {„quick“: „echo the quick brown fox jumps“}; quick gives the output „the quick brown fox jumps“; can be used for predefined commands like TP0/TP1 (turn off/on power for teleprinter) |
Terminal | portname | "/dev/ttyUSB0" | string | serial port used |
Terminal | baudrate | 300 | number | Baud rate |
Terminal | bytesize | 8 | number | # of Databits |
Terminal | stopbits | 1 | 1, 1.5, 2 | # of stopbits |
Terminal | parity | "NONE" | "NONE" / "ODD" / "EVEN" | parity bit |
Terminal | loc_echo | true | false / true | if true, echo back all characters |
Terminal | dsrdtr | false | false / true | if true, use DSR/DTR handshake |
Terminal | rtscts | false | false / true | if true, use RTS/CTS handshake |
Terminal | xonxoff | false | false / true | if true, use XON/XOFF handshake |
Terminal | RS485 | false | false / true | if true, use RS485 protocol |
Terminal | send_only | false | false / true | if true, receiving is inhibited |
Terminal | auto_CRLF | 0 | 0..N | if >0, insert CR/LF after N characters |
Terminal | replace_char | {} | dict | Translation table for special characters, structure see "ShellCmd" |
Terminal | replace_esc | {} | char | Sequence to use as ESC character |
Terminal | show_BuZi | true | false / true | If true, show special characters for Bu / Zi on terminal |
Terminal | show_ctrl | true | false / true | if true, show control sequences on terminal |
Terminal | show_info | false | false / true | if true, show additional info on terminal |
consumer_key | ? | |||
consumer_secret | ? | |||
access_token_key | ? | |||
access_token_secret | ? | |||
follow | ? | |||
track | ? | |||
languages | ? | |||
url | ? | |||
host | ? | |||
port | ? | |||
TwitterV2 | consumer_key | none | string | |
TwitterV2 | consumer_secret | none | string | |
TwitterV2 | access_token | none | string | |
TwitterV2 | access_token_secret | none | string | |
TwitterV2 | bearer_token | none | string | |
TwitterV2 | user_mentions | none | string |
Consider using release packages for software installation: https://github.com/fablab-wue/piTelex/releases
-
Local use
-
i-Telex
-
Advanced Topics
-
Tools & Gadgets
-
TW39 (current loop)
-
ED1000 (FSK modulation)
-
V.10 (TeKaDe FS200, FS220)
-
SEU-M-board based
- with Austrian AGT (Ö-AGT, current loop)
- as replacement for SEU-B card inside LO2000, LO2001, LO3000