This discussion assumes that you have setup and debugged your hardware configuration. A detailed discusion can be found under Hardware Configuration.

Before using your MMU you will need to calibrate it to adjust for differences in components used on your particular build. Be careful to calibrate in the recommended order because some settings build and depend on earlier ones. Happy Hare now has automated calibration for some of the traditionally longer steps and does not require any Klipper restarts so the process is quick and painless.


#f03c15 #c5f015 #1589F0 Calibration Steps

Important

When calibrating the first time you must perform in the prescribed order. Once complete you can re-calibrate particular steps but remember that some calibration changes will cascade. E.g. after calibrating the gear, you must recalibrate the encoder, the bowden and possibly all the gates. Generally you can re-calibrate the selector (step 1) and the gates (step 5) at any time, but the gear, encoder and bowden must always be done in that order!

graph TD;
    Hardware_Working --> MMU_SERVO["2.MMU_SERVO<br/><span style='font-size:10px'>(if fitted)</span>"]
    Hardware_Working --> MMU_CALIBRATE_SELECTOR["1.MMU_CALIBRATE_SELECTOR<br/><span style='font-size:10px'>(if MMU has a selector)</span>"]
    MMU_CALIBRATE_SELECTOR --> MMU_CALIBRATE_BOWDEN
    MMU_SERVO --> MMU_CALIBRATE_GEAR["3.MMU_CALIBRATE_GEAR<br/><span style='font-size:10px'>(can use on every gate to set rotation_distance)</span>"]
    MMU_CALIBRATE_GEAR --> MMU_CALIBRATE_ENCODER["4.MMU_CALIBRATE_ENCODER<br/><span style='font-size:10px'>(if MMU has an encoder)</span>"]
    MMU_CALIBRATE_ENCODER --> MMU_CALIBRATE_BOWDEN["5.MMU_CALIBRATE_BOWDEN<br/><span style='font-size:10px'>(can use to set length on every gate)</span>"]
    MMU_CALIBRATE_BOWDEN --> MMU_CALIBRATE_GATES["6.MMU_CALIBRATE_GATES<br/><span style='font-size:10px'>(available if MMU has an encoder)</span>"]

    style Hardware_Working stroke-width:0px
    style MMU_SERVO stroke-dasharray: 5 5, stroke:#c5f015, stroke-width:2px
    style MMU_CALIBRATE_SELECTOR stroke-dasharray: 5 5, stroke:#c5f015, stroke-width:2px
    style MMU_CALIBRATE_ENCODER stroke-dasharray: 5 5, stroke:#1589f0, stroke-width:2px
    style MMU_CALIBRATE_GATES stroke-dasharray: 5 5, stroke:#1589f0, stroke-width:2px
Loading
  • MMU designs with disimilar rotation_distance on each gate require separate measured calibration of each with MMU_CALIBRATE_GEAR or, if an encoder is fitted, with MMU_CALIBRATE_GATES to automate the process. This is important even if the drive gears look similar. Tradrack is an example of a design that doesn't require this.
  • Most MMU designs will share the same bowden length (and only one need be calibrated), however if the design can have different lenghts each must be calibrated separately.

Tip

All of the calibration commands can be run in a "check/test" mode. Simply add SAVE=0 to the command and the calibration will be run but the results will not be saved. This is very useful to practice or to verify calibration


#f03c15 #c5f015 #1589F0 Step 1. Calibrate selector offsets

Only application to MMU's with linear selector: E.g ERCF, Tradrack

A) Fully automatic calibration

Let's start by getting the selector cailbrated in this easy step (it is important to do this early because the bowden and gate calibration need to be able to select gates). This sets up the position all of all the gates as well as the bypass position if fitted. Firstly ensure MMU motors are off by running MMU_MOTORS_OFF and remove filament from gate #0 -- you may need to run MMU_SERVO POS=up to release the filament. Then re-insert and remove filament through selector to ensure that gate #0 is correctly alined with selector. Be careful and move the selector side to side whilst moving the filament inside the gate. Try to assess where the filament is centered in the gate and leave the selector in that position. Then run:

MMU_CALIBRATE_SELECTOR

Sit back and relax. The selector will move to find the extremes of movement and then use information about the geometry of the particular MMU and version/options you are using to generate and save the selector offsets automatically!

Note

(i) ERCF v1.1 users need to pay particular attention to letter suffixes after the version number in mmu_parameters.cfg
(ii) ERCF v1.1 users that are using a bypass block modification also need to specify the position of that block with BYPASS_BLOCK= (see command reference) to indicate which bearing block contains the bypass.


B) Extrapolate first and last gates

Although the above automated method above will attempt to calibrate when the selector has no deterministic hard stop at limit at travel (Tradrack) it can result in drift unless all the gates/lanes are perfectly tight together. To address this a better method that can be used with Tradrack or any MMU design with equally spaced gates (e.g. ERCF v2) is as follows:

MMU_MOTORS_OFF
  # Use a piece of filament to align gate 0; remove filament
MMU_CALIBRATE_SELECTOR GATE=0
MMU_MOTORS_OFF
  # Use a pieve of filament to align the last gate; remove filament
MMU_CALIBRATE_SELECTOR GATE=n
  # (where n is the last gate number, remember we are 0 based)

This will automatically set the offset of all intermediate gates distributing any build variance


C) Individual gate calibration

Although it should not be necessary other than for the bypass gate, there is an option update a single position if you would like to tune or run into problems. See the command reference for more detailed information on options, but basically you turn MMU motors off, line up the desired gate with the selector and run:

MMU_CALIBRATE_SELECTOR SINGLE=1 GATE=...

Strictly speaking SINGLE=1 is only required if calibrating just your final gate to avoid automatic extrapolation.

D) Individual bypass gate calibration

Similar to the above if your MMU has a bypass gate you can calibrate it's position by aligning the selector and running:

MMU_CALIBRATE_SELECTOR BYPASS=1

Validation: At the end of this step you should be able to select any tool/gate on your MMU. For instance, try running MMU_HOME TOOL=3 to re-home and select tool/gate #3.


#f03c15 #c5f015 #1589F0 Step 2. Calibrate your servo

Only applicable to MMU's with linear selector: E.g ERCF, Tradrack

Happy Hare sets up theoretically good servo postions during installation, however they really should be calibrated. Most MMU's require precise servo movement. To do that you need to run through this process similar to this to update and record the angle for the three symbolic positions. Be sure to consult you MMU documentation.

MMU_SERVO POS=up
  # Assume the position isn't quite right
MMU_SERVO
Current servo angle: 125, Positions: {'down': 110, 'up': 125, 'move': 110}
  # Without arguments you can view the current angles
MMU_SERVO ANGLE=128
  # Tweak until you are happy with position
MMU_SERVO POS=up SAVE=1
  # Save the current angle (128) for the "up" position

Repeat for the three positions:

  • up = tool is selected and filament is allowed to freely move through gate
  • down = to grip filament
  • move = ready the servo for selector move (optional - defaults to up)

Note

Refer to you specific MMU doc for information to determine exactly what servo positions are required.
If you are unsure that your MMU requires a "move" position, set it the same as "up"
If you are unable to attain the servo angle required you might need to "change spline" or edit the servo configuration in mmu_hardware.cfg

Example servo positions on ERCF MMU design
Ignore this if not on an ERCF, but this might be helpful to many users. Make sure the 3 position of your servo arm so the arm does not hit the tophats when the selector is moving. See picture below to find out where the position should be for the 3 positions.

  • Servo Up. (trap released / print without sync)

Servo Up

  • Servo Move. (trap locked / selector movement)

Servo Move

  • Servo Down. (trap released for Load/unload or print with sync mode)

Servo Down


#f03c15 #c5f015 #1589F0 Step 3. Calibrate your gear stepper

Applicable to all MMU's: Very important to get right!

In this step you are simply ensuring that when the gear stepper is told to move 100mm of filament it really does move 100mm. It is akin to what you did when you set up your extruder rotational distance although in this case no Klipper restart is necessary! Select gate #0 (you can use MMU_SELECT GATE=0 if you have finished the selector calibration above) and put some filament through the gate so that it pokes out just past the selector exit. Run the following to ensure the filament is gripped if your MMU needs to actuate a servo to grip filament:

MMU_SERVO POS=down

Next remove the bowden tube and cut the filament flush with the ECAS connector at the output of the MMU (e.g the encoder on the ERCF design). Run this command to attemp to move 100mm of filament:

MMU_TEST_MOVE MOVE=100

Get out your ruler and very carefully measure the length of the emited filament. Hold your ruler up to the bowden and gently pull the filament straight to get an accurate measurement. Next run this specifying your actual measured value (102.5 used in this example):

MMU_CALIBRATE_GEAR MEASURED=102.5

    Gear stepper 'rotation_distance' calculated to be 23.117387 (currently: 22.9)
    Gear calibration for gate 0 has been saved

Note

You can also measure over a different length by using something like MMU_TEST_MOVE MOVE=200 and MMU_CALIBRATE_GEAR LENGTH=200 MEASURED=205.25 for a 200mm length for example.

Validation: If you want to test, snip the filament again flush with the ECAS connector and run MMU_TEST_MOVE. Exactly 100mm should be moved this time.

Repeat for all other gates if your MMU has variable gears (not necessary on Tradrack). However if you have an encoder you can shortcut and use MMU_CALIBRATE_GATES discussed later.


#f03c15 #c5f015 #1589F0 Step 4. Calibrate your encoder

Applicable if fitted: All ERCF, Tradrack Binky Mod, etc

If your MMU includes an encoder (like the ERCF design) the next step is to calibrate so it measures distance accurately. Re-fit the bowden to the selector/encoder (you can insert the short length of filament to tube as you fit to save time). Alternatively, just make sure you have some filament at gate #0 before starting. Now run:

MMU_CALIBRATE_ENCODER

You will see an output similar to:

    Calibrating over 400mm...
      + counts: 368
      - counts: 368
      + counts: 369
      - counts: 369
      + counts: 369
      - counts: 369
    Load direction:   mean=368.67 stdev=0.58 min=368 max=369 range=1
    Unload direction: mean=368.67 stdev=0.58 min=368 max=369 range=1
    Before calibration measured length: 394.47mm
    Calculated resolution of the encoder: 1.085049 (currently: 1.094543)
    Encoder calibration has been saved

Note

(i) Use fresh filament - grooves from previous passes through extruder gears can lead to slight count differences.
(ii) Make sure the selector is aligned with the gate. If it is off to one side you will almost certainly get disimilar counts in forward and reverse directions.
(iii) You want the counts on each attempt to be the same or very similar but don't sweat +/-3 counts. With ERCF v2.0, sprung servo and new Binky encoder design they should be very consistent though ;-)
(iv) You can run this (like all calibration commands) without saving the result by adding a SAVE=0 flag.

If this step worked then you should be able to unload the residual filament with MMU_UNLOAD. If you aren't happy with results, leave the filament ready for the next run.


#f03c15 #c5f015 #1589F0 Step 5. Calibrate bowden length

Applicable to MMU's with fast bowden move: Most designs except Angry Beaver

The last calibration before use! Here you can calibrate the length of your bowden from MMU gate to extruder entrance. This is important because it allows the MMU to move the filament at a fast pace over this distance because getting to the more complicated part of the load sequence. To speed up this process you need to give the calibration routine a hint of how far way the extruder is (but not exceeding the distance). A good rule of thumb is to manually measure the distance from exit from the selector to the entrance to your extruder. Subtract 40-50mm from that distance. I measured approximately 690mm on my system, so will supply 650mm as the starting value. In you have an encoder you can run the automatic method:

MMU_CALIBRATE_BOWDEN BOWDEN_LENGTH=650

    Homing MMU...
    Tool T0 enabled
    Calibrating bowden length from reference Gate #0
    Tool T0 enabled
    Heating extruder to minimum temp (200.0)
    Finding extruder gear position (try #1 of 3)...
    Run Current: 0.21A Hold Current: 0.09A
    Run Current: 0.49A Hold Current: 0.09A
    Pass #1: Filament homed to extruder, encoder measured 683.5mm, filament sprung back 3.2mm
    - Bowden calibration based on this pass is 683.5
    Finding extruder gear position (try #2 of 3)...
    Run Current: 0.21A Hold Current: 0.09A
    Run Current: 0.49A Hold Current: 0.09A
    Pass #2: Filament homed to extruder, encoder measured 682.7mm, filament sprung back 3.2mm
    - Bowden calibration based on this pass is 682.7
    Finding extruder gear position (try #3 of 3)...
    Run Current: 0.21A Hold Current: 0.09A
    Run Current: 0.49A Hold Current: 0.09A
    Pass #3: Filament homed to extruder, encoder measured 683.9mm, filament sprung back 3.2mm
    - Bowden calibration based on this pass is 683.4
    Recommended calibration reference is 680.2mm. Clog detection length: 16.8mm
    Bowden calibration and clog detection length have been saved

If you don't have an encoder or have problems with collision detection at the extruder you can run manually. To do this, select gate 0, push filament through manually all the way to the extruder gears. This run with the MANUAL=1 option:

MMU_CALIBRATE_BOWDEN BOWDEN_LENGTH=650 MANUAL=1

This will reverse homes to the gate and use Klipper's measurement of stepper movement. This is the method for MMU designs like Tradrack that don't have encoder but do have mmu_gate sensor.

Note

(i) This calibration assumes that the selector has been calibrated first.
(ii) This may cause the extruder to be heated. This is to ensure that the extruder motor is energized and can resist the impact of the collision with the filament


#f03c15 #c5f015 #1589F0 Step 6. Calibrating individual gates

Applicable to MMU's with varible per-gate rottion distance & encoder: ERCF, Tradrack with Binky

This step allows for calibrating slight differences between gates and saves you from having to use MMU_CALIBRATE_GEAR on every gate. It isn't required (or useful) for designs that cannot have variation like the Tradrack MMU but is useful for designs like ERCF that can have variation of feed between gates. Even with ERCF this is optional because if not run, the gates will tune themselves as they are used automatically! That said it be beneficial to get this out of the way with a test piece of filament but doing it also: (i) removes the need to set the autotune_rotation_distance in mmu_parameters.cfg, (ii) is necessary if there is substantial variation between gates -- e.g. if BMG gears for different gates are sourced from different vendors.

Simply make sure filament is available at the gate you want to calibrate -- you can hold a (500mm) loose piece of filament and run:

MMU_CALIBRATE_GATES GATE=1

You will see an output similar to:

    Tool T1 enabled
    Calibrating gate 1 over 400.0mm...
      + measured: 404.4mm
      - measured: 404.4mm
      + measured: 404.4mm
      - measured: 404.4mm
      + measured: 405.5mm
      - measured: 405.5mm
    Load direction:   mean=404.7 stdev=0.63 min=404.4 max=405.5 range=1.1
    Unload direction: mean=404.7 stdev=0.63 min=404.4 max=405.5 range=1.1
    Calibration move of 6x 400.0mm, average encoder measurement: 404.7mm - Ratio is 1.011872
    Calculated gate 1 rotation_distance: 22.941324 (currently: 22.672165)
    Calibration for gate 1 has been saved

Note

(i) You can also quickly run through all gates (even pass the loose filament gate to gate) with MMU_CALIBRATE_GATES ALL=1
(ii) If you see "Calibration ignored because it is not considered valid (>20% difference from gate 0)" then it either means the calibration failed because filament was not moving or the encoder was not working correctly. Less likely but possible is because you have not calibrated gate 0 (MMU_CALIBRATE_GEAR and MMU_CALIBRATE_ENCODER) correctly which serves as the reference gate.


#f03c15 #c5f015 #1589F0 Calibration Storage

All calibrated results are stored in the configured [save_variables] file. By default and most usually this will be the mmu_vars.cfg. Here is a list of those variables and the command that sets them:

Variable Command Notes
mmu_selector_offsets MMU_CALIBRATE_SLECTOR A list of offsets for each gate of the MMU
mmu_selector_bypass MMU_CALIBRATE_SELECTOR The offset of the bypass (passthough) location
mmu_servo_angles MMU_SERVO E.g {'down': 45, 'up': 125, 'move': 110} represents the angles for the three servo positions
mmu_gear_rotation_distances MMU_CALIBRATE_GEAR or MMU_CALIBRATE_GATES The list represents rotation_distance for each gate
mmu_encoder_resolution MMU_CALIBRATE_ENCODER The distance each encoder signal transition represents
mmu_calibration_bowden_home MMU_CALIBRATE_BOWDEN Records the gate homing endstop used as a basis for the calibration
mmu_calibration_bowden_lengths MMU_CALIBRATE_BOWDEN The list will be the same length as the number of gates on your MMU
mmu_calibration_clog_length MMU_CALIBRATE_BOWDEN Only used with encoder although always set incase you add in the future
 1. Introduction
 2. Installation
 3. Essential Configuration
 4. Calibration
 5. Operation

-- YOUR MMU IS READY TO PLAY WITH --